N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
D Series Air, Water or Remote User Manual
December 2014
Page 19
Bearing Service
This task should only be done by a qualied service
technician
If the grease is uniformly white, no further action is
needed. If very gray, rusty, wet or has any embedded
metal, have the bearing replaced.
If the bearing only needs grease, or to conrm the
quality of the grease low in the bearing, inject grease
into the lower part of the bearing using Scotsman
grease needle pn 02-3559-01 and Scotsman bearing
grease cartridge, pn A36808-001. Be sure to inject
grease evenly and thoroughly.
Change De-Scale Notication Interval
This feature is accessible only from standby
(Status Light Off).
1. Press and hold Clean button for 3 seconds.
This starts the Time to Clean Adjustment State and
displays the current time to clean setting.
2. Press the clean button repeatedly to cycle through
the 4 possible settings:
• 1 year
• 0 (disabled)
• 4 months
• 6 months(default)
3. Push Off to conrm the selection.