N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
D Series Air, Water or Remote User Manual
December 2014
Page 14
Water - Remote Models
The water supply for ice making must be cold, potable
water. There is a single 3 8” male are potable water
connection on the back panel.
Backow
The design of the oat valve and reservoir prevents
potable water backow by means of a 1" air gap
between the reservoir's maximum water level and the
oat valve water inlet orice.
Drain
There is one ¾” FPT condensate drain tting at the
back of the cabinet.
Attach Tubing
1. Connect the potable water supply to the potable
water tting, 3 / 8” OD copper tubing or the
equivalent is recommended.
2. Change the cartridge on the existing water lter (if
any present).
3. Connect the drain tube to
the condensate drain tting.
Use rigid tubing.
4. Vent the drain tubing
between the ice machine
and the building drain.
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser. Be sure to vent the bin drain.
Follow all local and national codes for tubing, traps
and air gaps.
To Remote Condenser
Potable Water
Connection
Drain Vent
Condensate Drain