April, 2016
Page 17
C0530E through C1030E
Remote Condenser Models - User Manual
Control Switches
The On and Off Switches are accessible from the
front of the machine.
To switch the machine OFF, push and release the Off
button. The machine will shut off at the end of the next
cycle.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
Control Options
There are two optional, eld installed controls that can
be on this machine.
VariSmart™ adjustable ice level control
SmartBoard™ advanced control board and data
logger
Optional adjustable ice level control (KVS)
When this option is present there is an adjustment
post and an additional indicator light to the right of the
four indicator lights mentioned above. The ultrasonic
ice level control allows the user to control the point
that the ice machine will stop making ice before the
bin or dispenser is full. Reasons for this include:
Seasonal changes in ice used
Planning to sanitize the bin
Faster turnover for fresher ice
Certain dispenser applications where maximum
ice level is not desired
Use of adjustable ice level control
There are several positions the ice level can be set
to, including Off (knob and label indicators lined up),
where it lls the bin until the standard bin control shuts
the machine off. See the kit’s instructions for complete
details.
Rotate the adjustment post to the desired ice level.
The machine will ll up to that level and when it shuts
off the indicator light next to the adjustment post will
be on.
Note: Ice will build up in the bin or dispenser at an
angle, the distances listed above will be from the
sensor to the top of the ice directly beneath it.
The actual distance between the highest point of the
ice may be closer or further away, depending upon
the angle of the ice.
Adjust Ice Level
Bin
Full
N
o
r
m
L
o
w
e
r
02-4294-01
Graphic Rev. B
Rotate knob to set ice level
Yellow Arrow = Max Ice
White Arrow = Min Ice
Left Green = Dispenser high
Norm = Lower in Dispenser