27
Safety distance (S)
The minimum distances between the highest part of a cooktop (including
trivets, dials - depending on model) and the bottom of the rangehood are as
follows, unless a greater distance is specified by the manufacturer of your
cooking appliance. See also "Warning and Safety instructions".
Cooking appliance Minimum distance S
Electric cooktop 600 mm (AU, NZ)
450 mm (HK, MY, SG)
Electric grill, deep fat fryer (electric) 650 mm
Multi-burner gas cooktop with maximum 45.4MJ/h total
output, with no burner having a greater output than
16.2MJ/h.
650 mm
Multi-burner gas cooktop with total output greater than
45.4MJ/h, but with a maximum of 77.8MJ/h, with no
burner having a greater output than 17.3MJ/h.
760 mm
Multi-burner gas cooktop with total output greater than
77.8MJ/h, with a single burner having a greater output
than 17.3MJ/h.
Not possible
Single burner gas cooktop with a maximum output of
21.6MJ/h.
650 mm
Single burner gas cooktop with an output greater than
21.6MJ/h, but with a maximum of 29.2MJ/h.
760 mm
Single burner gas cooktop with an output greater than
29.2MJ/h.
Not possible