Robinhood HED604FKG 60cm Ceramic Cooktop

Installation and operating instructions - Page 4

For HED604FKG.

PDF File Manual, 12 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Installation - continued
Installation procedure.
Worktop must be placed absolutely horizontal.
Suitably protect the edges of the cut aperture.
Connect the cooktop to the mains power supply (see instructions for the connection of the cooktop to the mains power
supply).
Insert the cooktop into the cut aperture.
Press the cooktop firmly towards the worktop from above.
Connection to the power supply.
Connections must be carried out by a qualified electrician only. The earth protection must comply with the national
regulations.
1. Connection terminals are revealed when the connection box cover is removed.
2. Prior to any attempted connection check that the voltage indicated on the rating plate is in line with your home power
supply.
The rating plate is located underneath the appliance.
The appliance is manufactured for use with the power supply voltage 220-240 V~.
3. The electric wiring should be equipped with a circuit breaker able to isolate the appliance from the mains in all points,
with the distance between terminals of at least 3 mm in open position. This may be done by means of fuses, safety
switches, etc.
4. The connection should be selected in accordance with the declared charge capacity of the mains and the fuse power.
5. Such appliances are allowed to be mounted on one side next to a high kitchen cabinet, the height of which may
exceed that of the appliance. On the opposite side however, only a kitchen cabinet of equal height as the appliance is
allowed.
6. Upon the completion of installation, live wires and isolated cables must be adequately protected against accidental
touching.
7. In accordance with the mains voltage, the appliance should be connected in line with the attached diagram.
8. The earth wire (PE) must be connected to the terminal marked with the earth symbol .
9. Connection may be carried out means of harmonized cables as H05V2V2-F (90°C), or with equal or better features.
10. The power cable must lead through the relief safety device, protecting it from accidental pull out.
11. Upon the completion of installation switch all the hotplates on for about 3 minutes to check the proper functioning
Attention
Only qualified electricians should attempt any repairs on the appliance, always disconnect the power supply beforehand.
Loading ...
Loading ...
Loading ...