Loading ...
Loading ...
Loading ...
Other Functions
Environmental protection function:
If no operation is detected within 60 seconds, all LED’s dim to a semi-bright light.
When operation is detected, the LED’s enter full brightness immediately.
Water level protection function:
When the cooling function is rst turned on, the water pump works for 50 seconds.
If the low water is detected, then the pump will stop working and a buzzer alarm
sounds for 10 seconds.
Air dry function
If the honeycomb lter needs to be dried after using the cooler/humidier function
(e.g. before packing the unit away), press and hold the “fan speed” button on the
panel for 3 seconds to activate the air dry function.
When the air dry function is activated, the fan speed turns to high speed
automatically and runs for 20 minutes. During ‘Air dry’, other functions are turned
o and can not be used. The high fan speed indicator will illuminate and ash for the
20 minute duration.
If the “On/O” button is pressed before the 20 minutes are complete, the remaining
‘Air dry’ time won’t be saved, and you’ll need to start again.
Power failure memory function:
If there is a power failure during operation, when power resumes, the unit will
automatically turn back on and beep ten times. After 30 seconds the unit will
resume the last settings it was operating in. Note: the previous function will be
restored (except if in sleep mode).
To speed up the process, press the “On” button within 30 seconds of the power
being restored, and it will operate immediately.
Prevent long time use
The unit turns o automatically after continuously working for 15 hours. This function
can prevent the unit from running for long periods, especially if the user forgets to
turn the unit “O”.
Uninterrupted memory function:
When hen the power is restored after a power outage, a beep will sound 10 times (1
time per second) without display and action. After 30 seconds, the unit will restore
to the previous settings. Note: the previous function will be restored (except if in
sleep mode).
If the power button is pressed during the 30 second waiting time, the previous state
will be restored immediately.
The timer countdown should also be memorised and an error of no more than 5 min
is permitted for each power outage (o time duration is neglected).