ELECTRICAL
BRANCH
AWG
DISTANCE IN FEET FROM MOTOR TO SUPPLY
MAX. LOAD
FUSE
MIN. WIRE
0-100 101-200 201-300 301-400 401-500
MOTOR HP VOLTS AMP RATING AMP SIZE (mm
2
) AWG WIRE SIZE (mm
2
)
1/2 115/230 12.2/6.1 15/15 12/14 (3/2) 12/14 (8.4/2) 8/14 (2/2) 6/14 (14/2) 6/12 (14/3) 4/10 (21/5.5)
3/4 115/230 11.5/5.8 20/15 10/14 (5.5/2) 12/14 (8.4/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
1 115/230 11.9/6.0 25/15 10/14 (5.5/2) 6/14 (14/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
Motor Switch Settings (Figure 8)
Motors are designed to run on either 115 volt or 230 volt
current. Be sure switch is set properly for the incoming
voltage. SETTING SWITCH FOR INCORRECT VOLTAGE
WILL DAMAGE MOTOR AND VOID WARRANTY! IF YOU
DO NOT KNOW THE SUPPLY VOLTAGE CONTACT LI-
CENSED ELECTRICIAN.
Wiring Pressure Switch
Attach the wires from the power source to the pressure
switch following the directions provided under the cover
of the pressure switch. Remove the pressure switch cover
and follow wiring directions under the cover lid. Be sure to
ground wire is properly connected (Figure 9).
Disconnect power before working on
pump, motor, pressure switch or wiring
Motor may be hot. Allow to cool 20
minutes.
Water pressure may have built up in
the pump, pipes and/or tank. Drain
water to relieve pressure.
!
!
Wiring
Risk of electric shock.
Can shock, burn or kill.
1. To avoid dangerous or fatal electrical shock, turn OFF
power to circuit before working on electrical
connections.
2. Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
3. Supply voltage must be within +/- 10% of nameplate
voltage. Incorrect voltage can cause re or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
4. Use wire size specied in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
5. Do not ground to a gas supply line.
6. Wire motor according to diagram on motor nameplate.
If nameplate diagram diers from diagrams above,
follow nameplate diagram.
7. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
8. Pump must be on dedicated circuit with no other
equipment on circuit.
Wiring Chart Recommended Wire and Fuse Sizes for 115 and 230 volts
(Figure 9) Remove
Motor End Cover
to Access Voltage
Switch (some
models only)
Figure 8
Loading ...
Loading ...