Baumatic BCD925SS Range Cookers

User Manual - Page 41

For BCD925SS. Also, The document are for others Baumatic models: BCD920SS, BCD1020SS

PDF File Manual, 48 pages, Read Online | Download pdf file

BCD925SS photo
Loading ...
Loading ...
Loading ...
remove the blanking plug and refit it to the opposite side to
where the hose is being connected.
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a CORGI registered
engineer.
41
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Remove the pan-stands, burners and flame
spreaders (A).
o Unscrew the injector (B) and replace it with
the stipulated injector for the new gas supply
(see table below).
Operating
pressure gas
Rate Diameter
injector
Heat Input
(W)
By-Pass Burner
mbar g/h
L/h
1/100mm Min Max 1/100mm
G30 -
Butane
28 -
30
218
N/A
88 800 3000
G31 -
Propane
37 214
N/A
88 800 3000
Rapid
G20 -
Natural
20 N/A
286
117 - Y 800 3000
44
G30 -
Butane
28 -
30
131
N/A
68 600 1800
G31 -
Propane
37 129
N/A
68 600 1800
Semi -
rapid
G20 -
Natural
20 N/A
171
98 - Z 600 1800
34
G30 -
Butane
28 -
30
73 N/A
51 400 1000
G31 -
Propane
37 71 N/A
51 400 1000
Auxiliary
G20 -
Natural
20 N/A
95 75 - X 400 1000
28
G30 -
Butane
28 -
30
276
N/A
98 1400 3800
G31 - 37 272
N/A
98 1400 3800