11
The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would
typically result in the bottom of the hood
being 66” (167.6 cm) to 72” (182.9 cm)
above the floor. Refer to the range hood
installation instructions for additional
information. These dimensions provide for
safe and efficient operation of the hood.
66min.
(167.6 cm)
to
72max.
(182.9 cm)
30
(76.2 cm)
6
(15.2 cm)
Wood/Composite
Overlay
30min.
(76.2 cm)
to
36max.
(91.4 cm)
66min.
(167.6 cm)
to
72max.
(182.9 cm)
24
(61.0 cm)
Wood/Composite
Overlay
0
(
0 cm)
30min.
(76.2 cm)
to
36max.
(91.4 cm)
Wall Installation
Island Installation
Note: This range comes standard with an
Island Trim. There must be a minimum of
6” (15.2 cm) clearance from rear of range
to a combustible wall or 0” clearance to
a non-combustible wall.
Note: Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority
having jurisdiction.
Note: Minimum clearance for back
wall is 0” with backguard or high-
shelf.