Renogy RNG-DCC1212-20-CA Battery Charger

User Manual - Page 17

For RNG-DCC1212-20-CA.

PDF File Manual, 24 pages, Read Online | Download pdf file

RNG-DCC1212-20-CA photo
Loading ...
Loading ...
Loading ...
16
14.4 V
The 5 x dip switches can be configured to charge lead acid or lithium batteries. Note that ON is
position down and OFF is position up if facing the dip switches directly. Lead acid profiles have
an absorption charge and a float charge whereas lithium batteries will only have an absorption
charge and no float charge.
Lead acid assumes deep cycle AGM, Gel, Flooded, and Sealed Lead Acid. To get started,
make sure SW5 = ON to gear the charger for lead acid batteries. Next select your absorption
charge and float charge below by configuring the dip switches to your desired specifications.
ON
ON
OFF
SW1, SW2
DIP Switch Meaning
Set Absorption Charge Voltage
SW3, SW4
Set Float Charge Voltage
SW5
ON—Lead Acid
ON
OFF
ON
ON OFF
OFF
14.1 V
14.7V
OFF ON
DIP Switches
Setting Lead Acid
SW1 SW2
Set Absorption Charge
Voltage
13.8 VON ON
ON OFF
13.5 V
13.2V
OFF ON
SW3 SW4
Set Float Charge
Voltage
Loading ...
Loading ...
Loading ...