Fault Cause Troubleshooting
"E:36 / -25 / -26" Drain pump is blocked.
▶
→"Cleaning the drain pump",
Page42
The water pressure is low. No remedial action possible.
The filters in the water inflow
are blocked.
▶
"Clean the filters in the water in-
flow" →Page45.
The tap is turned off.
▶
Turn on the tap.
The water inlet hose is
kinked or jammed.
▶
Ensure that the water inlet hose is
not kinked or jammed.
flashes. The automatic voltage con-
trol system detects an unau-
thorised voltage under-us-
age.
▶
No remedial action possible.
Note:If the power supply is stable, the
programme continues to run as nor-
mal.
Voltage under-usage may
cause extension of a pro-
gramme.
No remedial action possible.
flashes. Voltage under-usage may
cause extension of a pro-
gramme.
No remedial action possible.
lights up. The temperature is too high.
▶
Wait until the temperature has
dropped.
▶
→"Cancelling the programme",
Page37
Water level is too high.
▶
Start the Drainprogramme.
Laundry is caught in the
door.
1. Open the door again.
2. Remove any trapped laundry.
3. Close the door.
4. Press Start/Reload to start the pro-
gramme.
flashes. Door is not closed. 1. Close the door.
2. Press Start/Reload to start the pro-
gramme.
All other error codes. Malfunction
▶
Call the after-sales service.
→"Customer Service", Page57
The appliance is not work-
ing.
The mains plug of the power
cord is not plugged in.
▶
Connect the appliance to the power
supply.
The circuit breaker is faulty.
▶
Check the circuit breaker in the
fuse box.