GAS CONNECTION - LP PIPED SYSTEMS
An LP piped system is one with a large central LP tank that feeds an entire household. These
systems are normally equipped with a high pressure regulator by the large LP tank, and low
pressure regulators close to the home. The gas line connectors must comply with the
Standard
for Connectors for Outdoor Gas Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
,
and suitable for outdoor installation. The connection shall be 48” (1.22 m) or less.
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply
pressure is adequate. The regulator must be set for a supply pressure of 11.0” WC (2.74 kPa) to
maintain 10.0” WC (2.49 kPa) outlet (manifold) pressure. Use a minimum 1/2” ID flex hose to
prevent gas starvation. Ensure that the service pipe supplying the Side Burner is fitted with a
shut-off valve conveniently positioned and easily accessible as an emergency gas shut-off.
1/2” ID FLEX HOSE,
ELBOW & NIPPLE
(SUPPLIED BY
CUSTOMER)
CONVERTIBLE
LP GAS
REGULATOR
INCOMING
LP GAS SUPPLY
SHUTOFF VALVE
(SUPPLIED BY
CUSTOMER)
HESTAN SIDE BURNER
(MODEL AGB122-LP SHOWN)
GAS AND ELECTRICAL CONNECTIONS
(continued)
Your Hestan Side Burner for use with an LP Piped System is supplied with its own convertible
regulator which MUST be installed. If this regulator needs to be replaced, use only the type
specified by Hestan for this appliance.
To connect the regulator follow the next steps:
1. Locate the regulator mounted underneath your Side Burner.
2. Connect gas supply using a minimum 1/2” diameter flexible (semi–rigid) stainless steel gas
hose, no more than 48” (1.22 m) in length. If you plan to inter-connect the Side Burner with
your Hestan Grill, be sure to use the fittings supplied with the mounting kit, and a flexible
hose as short as possible to make the connection. The hose as well as the connectors must
comply with the
Standard for Connectors for Outdoor Gas Appliances and Manufactured
Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation. Use the appropriate
thread sealant on all connections.
3. Proceed to LEAK TESTING section.