17
Descaling
Descaling the ultrasound membrane
Hard water can cause limescale to build up in the device and, especially, on the ultrasound membrane. This forms
white deposits. Descale the device regularly.
D
rop some descaler onto the ultrasound membrane.
L
eave it to take effect for two to five minutes.
C
lean the ultrasound membrane using the cleaning brush.
R
inse the base unit twice with clean, fresh water.
Cleaning inside the base unit
D
ip adamp, soft cloth briefly in descaling solution.
U
se the cloth to wipe the inside of the base unit.
C
arefully pour some clean, fresh water into the base unit.
E
mpty the water from the base unit via the side edge.
R
epeat the process using clean, fresh water.
Descaling the water tank
H
alf-fill the water tank with water.
A
dd asmall quantity of descaler.
T
ightly close the water tank using the screwed plug.
S
hake the water tank by rocking it back and forth several times.
E
mpty the descaling solution completely.
R
epeat the process twice using clean, fresh water.
8. Spare parts
Tip!
If the water is hard, we recommend using the optional anti-limescale filter.
Anti-limescale filter (optional).
Order number 163.803. Please contact the national service address.
Note
I
f the anti-limescale filter does not prevent limescale build-up, or if white deposits form on or in the device, the
anti-limescale filter should be replaced.
T
he service life of the anti-limescale filter is around two to three months at most.
I
f the device is not used for arelatively long time, the anti-limescale filter must be removed from the water tank
and dried out.
Fitting the anti-limescale filter
L
ift the water tank and rotate it.
O
pen the screwed plug on the water tank.
S
crew the anti-limescale filter onto the screwed plug on the inside.
T
ightly close the water tank using the screwed plug.
9. What if there are problems?
Problem Cause Solution
No LED display The mains cable is not plugged in. Connect the plug.
Red LED The water level is too low; the wa
-
ter tank is empty.
Fill the water tank.
No mist is produced The LED display lights red . Fill the water tank.