Loading ...
Loading ...
Loading ...
10
LEAK TESTING:
GENERAL:
Although all gas connections on your ALFRESCO™ Side Burner are leak tested at the factory prior to
shipment, a complete gas tightness check must be performed at the installation site due to possible mis-
handling in shipment, or excessive pressure unknowingly being applied to the unit.
Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.
To connect the piping or hose assembly follow the next steps:
 Locate the regulator and gas connection point in the rear side of your
Side Burner.
 Verify that the a 1/2” FPT x 1/2” MPT (male-to-female) connected to
the regulator points in the required direction. (see Figure # 3)
 Fasten the pipe or hose connection to a 1/2” MFT elbow with the ap-
propriate gas fittings. (see Figure # 3).
If the connection of the Side Burner is done with flare fittings and a flexible hose to the existing NG gas
supply, a 1/2” diameter flexible stainless steel gas hose, no more than 48” in length will be required.
WARNING
ENSURE THAT THE GAS
SUPPLY HOSE DOES NOT
COME IN CONTACT WITH
THE SIDE BURNER BODY
SHUT OFF HAND VALVE
MUST BE LOCATED IN
ACCESSIBLE AREA
INCOMING NG
GAS SUPPLY
Figure # 3
NG FLEXIBLE
HOSE OR
RIGID PIPE
CONVERTIBLE GAS
PRESSURE REGULATOR
SIDE BURNER UNIT
(COUNTER MOUNT)
1/2” FPT x 1/2” MPT
90° ELBOW