Display Alert Reason Solution
“X” pattern lashes one
time with one beep*.
One incorrect code entered. Re-enter code.
“X” pattern lashes
three times with three
beeps*.
No user code programmed. Program at least one user code.
Programming timeout after
20 seconds.
Attempt programming procedure again.
Unsuccessful programming.
“X” pattern lashes 15
times with 15 beeps*
Three incorrect codes
entered within one minute.
Re-enter code after 60 second
touchscreen lockout.
Checkmark and
lock symbols lash
simultaneously ive
times with long
continuous beep*.
Low battery. Replace batteries.
Checkmark and lock
symbols alternate
lashing ive times with
long continuous beep*.
Door jammed while
attempting to lock.
Manually re-lock door. If needed,
reposition strike.
N/A
Lock beeps
continuously.
Interior assembly is
disconnected from exterior.
Remove battery pack, reconnect the interior
to the exterior, then replace battery pack.
Status
LED
If the touchscreen indicates a failure, see the
online Programming and Troubleshooting Guide
or call Technical Support.
Note: All codes may be deleted at once if the mastercode is enabled. For more information about the
mastercode, consult the online Programming and Troubleshooting Guide.
© 2018 Spectrum Brands, Inc.
Exterior
Touchscreen
Checkmark
symbol
Lock
symbol
Emergency
Power 9 Volt Port
Success Failure
4 / 4
Obsidian at a Glance System Alerts
Switches and Status LED Colors
Deleting a single user code Factory Reset
*Beeping sound will only be heard if switch #3 is on.
If the screen is not pressed for 20 seconds, the system will time out, and you will need to restart the procedure.
A factory reset will delete all codes associated with the lock, and it will
remove it from your smart home system.
1. Read all instructions in their entirety.
2. Familiarize yourself with all warning and caution statements.
3. Remind all family members of safety precautions.
4. Protect your user codes and mastercode.
5. Dispose of used batteries according to local laws and regulations.
CAUTION: Prevent unauthorized entry. Since anyone with
access to the back panel can change the user codes, you must
restrict access to the back panel and routinely check the user
codes to ensure they have not been altered without your
knowledge. The use of a mastercode can help protect your
system’s settings.
WARNING: This Manufacturer advises that no lock can provide
complete security by itself. This lock may be defeated by
forcible or technical means, or evaded by entry elsewhere on
the property. No lock can substitute for caution, awareness of
your environment, and common sense. Builders hardware is
available in multiple performance grades to suit the application.
In order to enhance security and reduce risk, you should
consult a qualiied locksmith or other security professional.
Switch Function
1 Door lock status LED blinks every 6 seconds
2
Lock automatically re-locks door 30 seconds after
unlocking. Disabled if no codes are programmed.
3 Audio
4
SecureScreen feature displays random digits to be
pressed before entering user code. This added-
security feature ensures that there are ingerprints
on all digits so that codes cannot be identiied by
examining the touchscreen for ingerprints.
Color Lock Status
Blinking green Unlocked
Blinking amber Locked
Blinking red Low battery
Reference Guide
Important Safeguards
Back
panel
Button “A”
Program
button
Status
LED
Switches
Button “B
Turnpiece
shaft
Note: When the cover is removed,
the turnpiece shaft can be used to
manually lock and unlock the door.
If needed, the door handing process can be initiated manually.
This is useful if the lock is being moved to a dierent door.
Interior (cover removed)
1 2 3 4
On
Switches
Status
LED
O
Manual Door Handing
3 Press the Program
button once more.
4 The latch bolt
will extend and
retract to learn
the orientation
of the door.
1 Remove
battery pack.
2 Press and HOLD the Program
button while reinserting the
battery pack.
Release button once battery
pack is installed. The status LED
will lash red and green.
Status
LED
1 Remove
battery pack.
3 Press the Program button
once more. The status
LED will lash green and
red several times.
2 Press and HOLD the Program
button while reinserting
the battery pack.
Keep holding the button for 30
seconds until the lock beeps
and the status LED lashes red.
4 After a few seconds, the lock will
initiate the door handing process, and
the latch bolt will extend and retract
to learn the orientation of the door.
Removing the lock from the network
Press button "B" on the lock interior nine times.
1 Keep door open.
Press Program
button once.
2 Press Checkmark
symbol once.
3 Press Lock symbol
once.
4 Enter user code to
be deleted.
5 Press Lock symbol
once.
6 Re-enter user code. 7 Press Lock symbol
once.
If unsuccessful
Make sure to enter
the same valid code in
steps 4 and 6.
Test code
While the door is open,
test the user code to
make sure it no longer
unlocks the door.
Network InformationLow Battery
If the 4 AA batteries are too low to operate the lock,
use a 9Volt Alkaline battery to temporarily power the
touchscreen.
Make sure both terminals on the 9Volt battery touch the
terminals at the bottom of the touchscreen. Hold the 9Volt
in place while entering your user code to unlock the door.
Continue holding the 9Volt in position until the Checkmark
symbol illuminates and the door unlocks.
Note: If you remove the battery before the Checkmark
symbol illuminates, you will need to re-enter your user code
ZigBee System Notes
Zibee is a "Wireless mesh network", and results may vary based on
building construction and communication path with 36+ feet being
typical installed distance in a standard home environment and 250+
feet when the lock has a clear line of sight with the smart home
controller. It may be necessary to install additional Zigbee devices to
enhance the communication path between the lock and controller for
a more robust ZigBee network.