Complete Installation
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check that the range is level. See the “Level Range” section.
5. Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth. For more information, read
the “Range Maintenance and Care” section.
6. Read the Quick Start Guide and online Control Guide.
7. Turn on surface burners and oven. See the Quick Start Guide
and online Control Guide for specific instruction on range
operation.
If Range Does Not Operate, Check the Following:
Household fuse is intact and tight; or circuit breaker has not
tripped.
Range is plugged into a grounded 3-prong outlet.
Gas pressure regulator shutoff valve is in the “on” position.
Electrical supply is connected.
See the online “Troubleshooting” section.
8. When the range has been on for 5 minutes, check for heat. If
the range is cold, turn off the range and check that the gas
supply line shut-off valve is open.
If the gas supply line shut-off valve is closed, open it, and
then repeat the 5 minute test as outlined above.
If the gas supply line shutoff valve is open, press the
CANCEL button on the oven control panel and contact a
qualified technician.
If You Need Assistance or Service:
Please refer the “Quick Start Guide” for contact information.
GAS CONVERSIONS
Gas conversions from Natural gas to propane gas or from
propane gas to Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14ʺ (36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING:
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturers instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury
or loss of life. The qualified service agency
is responsible for the proper installation of
this kit. The installation is not proper and
complete until the operation of the
converted appliance is checked as
specified in the manufacturers
instructions supplied with the kit.