10
Countertop Installation
A - 13 inches maximum depth of overhead cabinets
B - 36 inches is minimum height of countertop above oor
C - The minimum at countertop surface that the grill will
rest upon must be equal to or greater than the overall
grill dimensions (refer to the page 8 for overall
grill dimensions).
D - 30 inches minimum clearance between the top of the
grill and the bottom of an unprotected wood or metal
cabinet or 24 inch minimum clearance when the
bottom of wood or metal cabinet is protected by not less
than 1/4 inch thick ame retardant mill board covered with
not less than No. 28 MSG sheet steel, 0.015 inch thick
stainless steel, 0.024 inch thick aluminum or 0.020 inch
thick copper.
E - 6 inches minimum from backsplash of countertop to edge of
grill (refer to the page 8 for overall grill dimensions).
1-1/2 inches minimum from front of counter to grill.
FOR INSTALLATIONS IN CANADA: “Do Not Install Closer
Than 1/2 Inch (13mm) From Any Adjacent Surface”, and NE
PAS INSTALLER A’MDINS DE 13MM DETOUTE SURFACE
ADJACENTE.
WARNING:
To eliminate the risk of burns from reaching over heated grill, cabinet storage space
located above the grill should be avoided. If cabinet storage is to be provided, the
risk can be reduced by installing a range hood that projects horizontally a minimum
of 5 inches beyond the bottom of the cabinets.
Fig. 6
Please read this section prior to making cutout for the grill.
It is important to plan ahead for installation of the grill, keeping the
following dimensions in mind (please refer to Figure 6 below).
Your Texan Grill is supplied with a factory installed polished stainless steel ange that accepts nine
oval head wood screws for mounting. The trim ange of the grill is designed to hold the unit rmly in
place in the countertop. If desired, you may seal the edge of the countertop beneath the trim ange.
We recommend a NON-ADHESIVE such as acrylic latex caulk. This will help reduce the chance
of damage to the trim ange should the unit need to be removed from the countertop. Should you
need to remove the unit from the countertop after installation simply take a piece of shing line and
run back and forth under the trim ange to break the caulk bond.