18
EN
INSTALLATION
Preparation
If you have an outlet to the outside, your cooker hood can
be connected as below picture by means of an extraction
duct (enamel, aluminium, exible pipe or inammable
material with an interior diameter of 150 mm).
Before installation, turn the unit off and unplug it from
the outlet.
The cooker hood should be placed at a distance of
65~75 cm above the cooking plane for best effect.
Installation (Vent outside)
Note: When the range hood and appliance supplied with energy other than
electricity are simultaneously in operation, the negative pressure in the room must be
not exceed 4 Pa (4 x 10
-5
Bar).
1 2
Drill 3 x 8 mm holes to accommodate
the bracket. Screw and tighten the
bracket onto the wall with the screws &
screw plugs provided.
Offer up the cooker hood and hang
onto the wall bracket hook.