US Stove Company 1500 2500-sq Heating Area Coal Furnace

User Manual - Page 6

For 1500.

PDF File Manual, 24 pages, Read Online | Download pdf file

1500 photo
Loading ...
Loading ...
Loading ...
6
© 2021 United States Stove Company
OPTIONAL EQUIPMENT
11DIKL DRAFT INDUCER KIT W/ LIMIT
SWITCH
This optional kit allows your furnace to be thermostatically
controlled and gives the option to change the on/o times
of the distribution blower(s).
UFB908 UNIVERSAL FILTER BOX
When installing ANY warm air furnace, proper installation
is the key and required for getting the most eciency and
longest life out of your unit. Failure to install your furnace
as outlined from the manufacturer, often will result
in inadequate heating and problems associated with
drafting. U. S. Stove Co. oers the UFB908, a universal
filter box that mounts to the rear of the unit that your
return air duct work will attach to. It uses a standard 16
x 20 x 1 filter (NOT INCLUDED) to reduce the amount of
dust particles from being transferred thru you duct work
system.
DR6 BAROMETRIC DAMPER REGULATOR
In the unlikely event that your furnace “overfires”
(a condition evidenced by elbows, stove pipes, and
connectors glowing red in appearance or otherwise
discoloring), then your installation is subject to excessive
draft created by either a chimney too tall or too great in
diameter in conjunction with its height, or some other
factor of an indeterminate cause. In this event, you should
install a barometric draft regulator. Such installation
will preclude any over-firing and/or any hazardous
consequences of potential overfiring. Barometric draft
regulators are generally available where you purchased
your stove or may be ordered directly from United States
Stove Company at a nominal charge.