Loading ...
Loading ...
Loading ...
37
Instructions for the installer
12.3 Burner and nozzle characteristics table
Burner
Rated heating
capacity (kW)
LIQUID GAS - G30/G31 28/37 mbar
Nozzle
diameter (1/100
mm)
Reduced
capacity (W)
Rated
(g/h G30)
Rated
(g/h G31)
Auxiliary 1.05 50 400 76 75
Semi-rapid 1.8 65 500 131 129
Rapid 3.0 85 800 218 214
Ultra-rapid 3.5 94 1600 255 250
Burner
Rated heating
capacity (kW)
NATURAL GAS - G20 20 mbar
Nozzle
diameter (1/100
mm)
Prechamber
(printed on
nozzle)
Reduced capacity
(W)
Auxiliary 1.05 72 (X) 400
Semi-rapid 1.8 97 (Z) 500
Rapid 3.0 115 (Y) 800
Ultra-rapid 3.5 133 (S) 1600
Loading ...