Mitsubishi SEZKD12NA4 Heat Pump

User Manual - Page 6

For SEZKD12NA4.

PDF File Manual, 25 pages, Read Online | Download pdf file

SEZKD12NA4 photo
Loading ...
Loading ...
Loading ...
6
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
A
B
DC
G
E
F
4
1
2
1
3 4
1 2
A Filter button (<Enter> button)
B TEST button
C Set Time button
D Timer On/Off button (Set Day button)
E Mode selection button
F Set temperature button
G Timer Menu button (Monitor/Set button)
Mode number
Setting number
Refrigerant address
Unit number
1
2
3
4
A For installation in the switch box:
B For direct installation on the wall, select one of the following:
Prepare a hole through the wall to pass the remote controller cord (in order to run the remote controller cord from
the back), then seal the hole with putty.
Run the remote controller cord through the cut-out upper case, then seal the cut-out notch with putty similarly as
above.
C Wall
D Conduit
E Lock nut
F Bushing
G Switch box
H Remote controller cord
I Seal with putty
J Wood screw
F
A
H
C
D
E
G
I
I
I
H
B
J
H
B-1. B-2.
[Fig. 8-5]
8
A
AB TB6
B
A To the terminal block on the indoor unit
B TB6 (No polarity)
[Fig. 8-6]
[Fig. 8-7]
8.2
8.4
46 [1-13/16]
30
[1-3/16]
120 [4-3/4]
83.5 [3-5/16]
A
B
C
30
[1-3/16]
30
[1-3/16]
A Remote controller
B Required clearances for the remote controller
C Installation pitch
[Fig. 8-4]
[Fig. 8-3]
A Indoor terminal block
B Ground wire (green/yellow)
C Indoor/outdoor unit connecting cable 3-
core 1.5 mm
2
[AWG 16] or more
D Outdoor terminal block
E Power supply cord
1 Indoor/outdoor unit connecting cable 3-
core 1.5 mm
2
[AWG 16] or more, fol-
lowing Design 245 IEC 57.
2 Indoor terminal block
3 Outdoor terminal block
4 Always install an ground wire (1-core
A Indoor terminal block
1.5 mm
2
[AWG 16]) longer than other cables
5 Remote controller cable
Wire No ¥ size (mm
2
) : Cable 2C ¥ 0.3
Accessory wire of remote controller
(wire length : 10m [32 ft], non-polar. Max. 500 m
[1640 ft])
6 Wired remote controller
7 Power supply cord
12
6
5
2
4
3
7
1
C Indoor/outdoor unit
connecting cable
3-core 1.5 mm
2
[AWG 16] or more
D Outdoor terminal block
B Ground wire (green/yellow)
E Power supply cord
8.3
(Unit: mm [in])
Loading ...
Loading ...
Loading ...