16
PERFORMANCE DATA SHEET
INTERIOR WATER SYSTEM
MODEL DW2042F-09 CAPACITY 300 GALLONS (1,135.62 LITERS)
System tested and certied by NSF International
against NSF/ANSI Standard 42 for the reduction
of Chlorine Taste and Odor, Particulate Class III.
This system has been tested according to the NSF/ANSI Standard 42 for the reduction of the substances listed below. The concentration
of the indicated substances in water entering the lter was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specied in NSF/ANSI Standard 42.
SUBSTANCE
REDUCTION
AESTHETIC
EFFECTS
NSF REDUCTION
REQUIREMENTS
AVERAGE
INFLUENT
INFLUENT
CHALLENGE
CONCENTRATION
MAXIMUM
EFFLUENT
AVERAGE
EFFLUENT
MINIMUM %
REDUCTION
AVERAGE %
REDUCTION
Chlorine Taste/
Odor
>50% 2.0 mg/L 2.0 mg/L ± 10% 0.05 mg/L 0.05 mg/L >97.4 % >97.6 %
Nominal
Particulate
Class III
>5 to <15 um
>85%
59,000
particles/
mL
At least 10,000
particles/mL*
95 particles/
mL
46
particles/
mL
99.8% 99.9%
Test parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa). Temp = 68°F to 71.6°F
(20°C to 22°C).
It is essential that operational, maintenance, and lter replacement requirements be carried out for the product to perform as
advertised.
The disposable water lter should be replaced at least every 6 months. Use replacement lter model DW2042FR-09. 2015 suggested
retail price of $44.99 U.S.A./$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Refer to the Back Cover for the Manufacturer’s name and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited warranty.
APPLICATION GUIDELINES/
WATER SUPPLY PARAMETERS
Water supply City or Well
Water Pressure 35- 120 psi (241 - 827 kPa)
Water Temperature 33° - 100°F (1°-38°C)
Service Flow Rate 0.50 gpm (1.89 Lpm.) @ 60 psi
* Test requirement is at least 10,000 particles/mL of ISO Coarse Test Dust.
® NSF is a registered trademark of NSF International.