Installation
English30
Installation check codes
Check code Meaning Solution
0 Vent condition is good.
Clg (Cg) The vent is clogged.
1. Clean the lint filter.
2. Check your vent condition. (Refer to
the “Ducting requirements” section)
* You must take measures (such as
cleaning) through expert personnel.
C80 (C8)
About 80 % of the vent is clogged. (This
may decrease the drying performance.)
C90 (C9)
Over 90 % of the vent is clogged. (This
may lead to poor drying performance or
cause malfunction)
Ct
The internal temperature of the dryer is
too low (below 32 °F (0 °C)) or too high
(over 104 °F (40 °C)) and therefore vent
blockage cannot be detected.
Leave the dryer at room temperature
(41~95 °F (5~35 °C)) for an hour and check
again.
tC Temperature sensor error. Contact a service center.
C1
Unit is detecting items inside the drum or
there is an error on the dry sensor.
Remove items from the drum and check
again.
If the problem continues, contact a
service center.
dC Unit is detecting door is open.
Close the door properly and check again.
If the problem continues, contact a
service center.
9C1 Abnormal voltage detected.
Check the power connection. (Refer to the
Connect the electrical wiring (for electric
models)” section)
If the problem continues, contact a
service center.
HC
Detection of abnormal temperature in
drum.
Check the power connection.
Check the vent condition if the problem
continue, contact a service center.