Dimplex BZT20E Fire

User Manual - Page 4

For BZT20E.

PDF File Manual, 5 pages, Read Online | Download pdf file

BZT20E photo
Loading ...
Loading ...
Loading ...
Important Safety Advice
When using electrical appliances, basic precautions
sh
ould be followed to reduce the risk of fire, electric
shock, a
nd injury to persons, including the following:
If t
he appliance is damaged, check immediately with the
supplier b
efore installation and operation.
Do n
ot use this heater in the immediate surroundings of
a b
ath, shower or swimming pool
.
Do not use outdoors.
This he
ater must not be located immediately above or
bel
ow a fixed socket outlet or connection box.
Do n
ot cover or obstruct in any way the heat outlet grille
located underneath the heater. Overheating will result if
the he
ater is accidentally covered.
In t
he event of a fault unplug the heater.
Un
plug the heater when not required for long periods.
The supply cord must be placed on the right hand side of
t
he h
eater away from the heat outlet underneath the
he
ater.
Although t
his heater complies with safety standards, we
do n
ot recommend its use on deep pile carpets or on
long h
air type of rugs.
This a
ppliance is not intended for use by children or other
persons w
ithout assistance or supervision if their
physic
al, sensory or mental capabilities prevent them
from usi
ng it safely. Children should be supervised to
ensure t
hat they do not play with the appliance.
The a
ppliance must be positioned so that the plug is
accessible.
If the su
pply cord is damaged it must be replaced by the
manufacturer o
r service agent or similarly qualified
person in order to avoid a hazard.
Caution: In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance must not
be supplied through an external switching device, such
a
s a tim
er, or connected to a circuit that is regularly
switched o
n and off by the utility.
The appliance must not to be located beneath a socket
o
utlet.
W
here a
n appliance is Recessed, necessity to allow
disconnection o
f the appliance from the electrical supply
is r
equired. Incorporate a switch in the fixed wiring in
accordance w
ith the Wiring regulations.
General
Unpack the heater carefully and retain the packaging for
possible future use, in the event of moving or returning the fire
to your supplier.
The fire incorporates a flame effect, which can be used with or
without heating, so that the comforting effect may be enjoyed at
a
ny t
ime of the year. Using the flame effect on its own only
requires little electricity.
Before connecting the heater check that the supply voltage is
the same as that stated on the heater.
Please note: Used in an environment where background noise
is very low, it may be possible to hear a sound which is related
to the operation of the flame effect. This is normal and should
not be a cause for concern.
Electrical
WARNING THIS APPLIANCE MUST BE EARTHED
Th
is heater must be used on an AC ~ supply only and the
voltage marked on the heater must correspond to the supply
voltage.
Do not switch the appliance on until properly installed.
Please
read all the safety warnings and operating instructions.
Bizet BZT20 Wall Fire
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Wall fixing - see Fig. 1
The appliance should be securely fixed to the wall using the
wall plugs and screws supplied for block walls.
N
ote f
or studded walls special fasteners are required, see
diagram for recommended position of fixing screws.
Recessed Installation
Please note that this appliance can also be wall-mounted so
th
at it is recessed. This can be installed in a large fireplace
opening or a purpose built wall. See Fig. 1 for size of recess
required and hole fixing dimensions.
This fireplace insert does
NOT require venting.
In order to ensure it’s future safety in use, it is essential that
this fire is securely fixed
to the wall.
IT IS IMPORTANT THAT THE FIXING DEVICE CHOSEN IS
A
PPROP
RIATE TO THE WALL MATERIAL TO WHICH THE FIRE
IS B
EING FIXED. SOME MODERN INTERNAL BUILDING
MAT
ERIALS ARE VERY LOW DENSITY BLOCK AND REQUIRE
SPECI
ALIZED FIXING DEVICES TO PROVIDE A SAFE,SECURE
INSTA
LLATION.
The installation of this fire should be carried out by a competent
person. If in doubt please consult your local builder.
This section provides step by step instructions for selecting a
location and preparing the site to install the fireplace into the
f
ollowing:
Existing Fireplace
1. Make sure that the fire is located on a flat surface.
2. Seal all draughts and vents to prevent chimney debris from
f
alling o
nto the Fireplace Insert. Do not install into an existing
fireplace that is prone to dampness.
3. Remove the front/trim by following the steps as outlined in
Lamp R
eplacement’ section.
4. Locate the 4 fixing holes, position the fire accordingly, and
f
irmly f
ix the appliance to the wall using the appropriate
screws.
5. Replace the front/trim.
New Support Structure Construction
When planning where to position your purpose built support
structure the following steps must be observed:
1.
Place the fire in the desired location to see how it will look in
the room.
2.
Mark the desired location for the new support structure in
t
he r
oom and store the fire in a safe, dry and dust free
locati
on.
3. Using timber studs to support the fire, devise and construct
a suitable means of supporting the product within the wall
partition and provide electrical power for the fire to be HARD
wired. For recommended sizes of height, width and depth
of opening for recess and hole fixing dimensions for each
model - see Fig. 1.
4. R
emove the front/trim by following the steps as outlined
previously.
5. Locate the 4 fixing holes, position the fire accordingly, and
firmly fix using the appropriate screws.
6. Replace the front/trim.
NOTE: The appliance should be HARD wired to an electrical
power outlet when placed in a recessed installation.
Please c
onsult a qualified electrician for appropriate wiring
requirements.
Loading ...