22
Rated Charging Current
Transformation
Input Battery Voltage Range
Idle power consumption
Residual ripple of output
voltage at rated current
Efficiency
Charging Voltage Range
Rated Max Power
8V ~ 16VDC
Lead Acid: 13.2V ~ 14.7V
Lithium: 12.6V ~ 14.6V
< 50 mV
90 %
0.4 A
-4 °F ~ 122 °F/
–20 °C to +50 °C
-3mV/C° /2V
M6 x 10mm
2.2 - 2.6 lbf - in /24.5 - 29.4 N - cm
20 A
40 A
60 A
250W
500W
750W
8.3 x 6.9 x 2.7 in /
211 x 175 x 68 mm
10.3 x 6.9 x 2.7 in /
261 x 175 x 68 mm
12.2 x 6.9 x 2.7 in /
311 x 175 x 68 mm
3 lbs. / 1.3 kg 4 lbs. / 1.9 kg 5.3 lbs. / 2.4 kg
Certification
Terminal Torque
Dimensions
Weight
Operational temperature
(Ambient)
≤95 % Non-condensing
Humidity
Temperature Compensation
Terminal Size
DCC1212-20Model DCC1212-40 DCC1212-60
12 V 12 V
Technical Specifications
The temperature compensation is not to be
used with lithium batteries.
NOTE
Temperature Compensation
V
0,4
0,2
0,2
0
0,4
0,6
0 54510155 3525 4030 0502
°C
12 V
CE
Loading ...