17
To get started, make sure SW5 = OFF to gear the charger for lithium batteries. There will not
be a float voltage and instead users will select between Type 1 lithium voltages or switch into
Type 2 lithium voltages depending on your lithium battery specifications. You must select a
lithium Type to when selecting your charge voltage. Type 1 voltages range from 12.6V ~ 13.0V
and Type 2 voltages range from 14.0V~14.6V.
Setting Lithium
14.6 V
SW2
DIP Switch
Lithium VoltageDIP Switch
Voltage
13.0V
SW5=OFF
14.4 V
14.2V
12.8 V
12.6V
14.0V
SW1
OFF
SW3 SW4
OFF
ON
ON OFF
OFF OFF
SW3
SW4
ON
SW1 SW2 Voltage
ON ON
OFF ON
ON OFF
OFF OFF
DIP Switch Lithium Voltage
Loading ...