Intex ZS6110 -120V Krystal ClearTM Ozone & Saltwater System

Owner’s Manual - Page 14

For ZS6110 .

PDF File Manual, 23 pages, Read Online | Download pdf file

ZS6110  photo
Loading ...
Loading ...
Loading ...
(328PO) MODEL ZS6110 OZONE & SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2019
328
PO
SAVE THESE INSTRUCTIONS
English
Page 14
6.
Boost cycle
After a heavy rain or if the pool is dirty, press and hold “BOOST” button
for 5 seconds until the indicator lights up and the LED display “80”.
This indicates that the Ozone & Saltwater system has started ozone
and more chlorine sanitizer production. You can press and hold the
“BOOST” button for another 5 seconds until the indicator is off, which
will cancel the Boost cycle.
The boost operating hours is 8 times the amount of time programmed into the system, i.e.
if your Ozone & Saltwater system operating time is 3 hours, the boost procedure will run
8 x 3 = 24 hours. After boost procedure has been completed, the system will automatically
switch to the normal working mode.
Once the boost is operating, check whether the filter pump operating hours have been set
properly. For example, the boost operating time is 16 hours, the filter pump should be set
to run for 17 hours at least. Increase the filter pump operating time if necessary.
Note:
If an Intex filter pump is attached to the system, set the pump switch to on “I” position.
7.
Test pool water regularly:
Test the pool water every week to maintain the proper sanitizer level.
It’s very important that the free chlorine is between 0.5-3 ppm.
8. Stand-by/power saving mode:
When the cycle ends, the green “SLEEP” indicator on the control panel
lights up and the LED display flashes “93”. The system is now in
Stand-By mode. After a while, it shuts down and sets itself in a Power
Saving mode. The system will automatically turn itself back on in
24 hours, starting its daily cycle of chlorine production.
The “SLEEP” indicator stays on, while the system is in the Power Saving
mode. The LED display however, goes blank after 5 minutes. Press any
button (
or ) to view the last LED code.
9.
Electrode Self-Clean cycle:
Press and hold
button for 5 seconds until the LED display flashes “10”.
Depending on your pool water calcium hardness level, press button
again to select the self-clean cycle time as below. Total of 3 settings:
14 hours, 10 hours and 06 hours.
NOTE:
The life of the cell varies depending on water conditions, pool usage and operating
time of the device. Select 14 hours cycle time to maximize the life of the electrolytic cell if
the calcium hardness level is up to 150 ppm. Manual routine cleaning and maintenance will
further lengthen the life of the electrolytic cell.
With the desired self-clean hours showing, press
button to lock the keypad controls and
the LED display will return to the normal operating time. The system will reverse the polarity
of the electrode
(5)
every time according to the selected hours.
NOTE:
If you forget to lock the keypad controls, the system will automatically lock it and start
working 5 seconds later.
OPERATION INSTRUCTIONS (continued)
Calcium Hardness Self-clean cycle time
0 - 150 ppm Reverse polarity every 14 hours
150 - 250 ppm Reverse polarity every 10 hours
250 - 350 ppm Reverse polarity every 06 hours
Loading ...
Loading ...
Loading ...