CONNECT THE WIRES (INTERNAL BLOWER)
Note: This range hood must be properly grounded. The unit should be installed by
a qualifi ed electrician in accordance with all applicable national and local electrical codes.
FIG.17
From
CBI-600A or
CBI-290A
Blower
A
B
C
FIG.18
From
PBI-1100A
Blower
A
CBI-600A, CBI-290A Wiring
PBI-1100A Wiring
1. Mount Capacitor box to hood body by (2) M4 x 8mm screws from blower hardware package.
2. Connect 6 pin female end from PCB box to 6 pin male end of capacitor box wiring. Connection A FIG. 17
3. Connect 9 pin male end from CBI blower to 9 pin female end of capacitor box wiring. Connection B FIG. 17
4. Connect green ground wire from capacitor box wiring to hood body by (1) 3/16 x 3/8 screw pre-installed
inside hood body. Connection C FIG. 17
CBI-600A and CBI-290A Connection
1. Connect 6 pin female end from PCB box to 6 pin male end PBI-1100A blower wiring. Connection A FIG. 18
PBI-1100A Connection