- 15 -
NON-DUCTED INSTALLATION ONLY
Note:
a. Purchase Model ANKWC345 Non-ducted
Recirculation Kit from your local dealer.
b. Rooms with 10 or 11 foot ceilings require
flue extension model AEWC345IQSBN,
available from your local dealer. Discard
the upper flue supplied with the range
hood and replace it with the longer flue
extension.
1. Install discharge collar supplied with the
range hood (Fig.17).
2. Attach the 6”-to-8” adapter to blower
discharge and tape joint with aluminum
duct tape (Fig.17).
3. Install the plenum to the upper decorative
flue using (4) 3.4 x 15 mm screws
provided as shown (Fig.18).
4. Attach 6-inch expandable ducting to the
plenum and tape joint with aluminum duct
tape (Fig.19).
5. Attach non-duct filter frame using (4) 3.9 x
6 mm screws (Fig.20).
MOUNTING SCREWS
(3.9 x 6mm Flat Head)
FIG. 20
DUCT
CONNECTOR
FIG. 19
FIG. 17
FIG. 18