User Manual Volta 6.5-100V

Documents for Volta 6.5-100V

The following documents are available:
User Manual Photos
6.5-100V photo
DROK DC Multimeter
http://www.Droking.com
Parameter:
Test range and display format:
200141
Operating voltage range: DC 6.5-100V
Measuring voltage range: DC 6.5-100V
Rated power: 100A/10000W
Accuracy: 1%
Shunt: 100A/75mV
Size pof Shunt: 107x23mm /4.2" x 0.9"
Wiring diagram:
Note:
Voltage Range: 6.5~100V (display 6.50~99.99V)
Key Operations:
Step 2. At this time, the energy display area flashes to indicate
that it is at “accumulated energy data reset” status.
Shunt range setting.
Cautions:
Recommend product
on Amazon:
DC Motor Controller
Any questions please
contact us through Amazon:
No load (only detect the voltage, no shunt or load connected):
Load
tested device
/power supply
100A/75mV shunt
84.6mm
44.6mm
49.6mm
84.6mm
24.4mm
51mm
30mm
This module is only applicable for 6.5~100V DC power.
The positive and negative pole of the power supply of the
meter can be directly connected to the positive and negative
pole of the power supply/tested device.
With load (connected with shunt and load):
Please note that the negative pole of the DC meter cannot be
directly connected to the negative pole of the power supply end.
It should be connected to the terminals of the external shunt.
Current Range: 0~100A (display 0.00~99.99A)
Power Range: 0~10kW
within 1kW, display 0.0~999.9W;
above 1kW, display 1000~9999W.
Energy Range: 0~9999kWh
within 10KWh, display 0~9999Wh;
above 10kWh, display 10~9999kWh.
Backlight Control.
Short press the key to turn on or turn off the backlight.
Backlight on/off status automatically saved when power off
Accumulated energy data reset.
Step 1. Hold press the key till the display area displays “CLr”,
and then loose the key.
Step 3. Short press the key, the accumulated energy will be
cleared, and it will stop flashing and exit reset status.
Alarm voltage value setting.
Step 1. Hold press the key till the power display area displays
“SET”, and then loose the key.
Step 2. At this time, the meter is at “alarm voltage value
setting” mode. The voltage display area displays the present
over-voltage alarm value, and the current display area
displays the present under-voltage alarm value, and the least
significant digit starts to flash.
Step 3. At this time, if short press the key, it will add 1 to this
digit.
Step 4. After setting the alarm value, hold press the key till the
screen displays “PASS” indicating set successfully and exit
the setting mode.
Please set the shunt range before using.
The attached shunt is 100A/75mV.
Step 2. At this time, the current display area displays “100A”.
Short press the key, it will switch between “100A” and “50A,
so as to indicate whether the range of the shunt is “100A/75mV
or “50A/75mV. Please note that only these two ranges of shunt
can be applied to this meter.
Step 3. Hold press the key until it exits the setting mode.
Or no key operation for 3 seconds, it will be automatically saved
and exit the setting mode.
The voltage and current of the load cannot exceed the
rated voltage and current of the meter.
Wiring order cannot be wrong.
Please connect the shunt to the negative terminal
according to the wiring diagram. If it is connected to
the positive terminal, it will cause internal short-circuit
or cannot function properly.
This meter is only suitable for indoor use. Please do
not use it outdoor.
Size:
Load
tested device
/power supply
100A/75mV shunt
Front
Back
If there is no key operation for 5 seconds, the accumulated
energy will NOT be cleared, and it will stop flashing and exit
reset status.
If no key operation for 3 seconds, it will automatically
switch the adjusting digit. There are 6 digits to be adjusted,
from the least significant digit to the most significant digit, from
the over-voltage value to the under-voltage value.
The settable alarm voltage value range is 6.5-99.9V.
Step 1. Hold press the key till the power display area displays
“CURR”, and then loose the key.
Summary of Contents for Volta 6.5-100V: