CLEANING OF THE SPRAY HEAD
Any deposits which may accumulate on the nozzle can be removed by simply running
a finger over the face of the sprayer and then running the water for a few seconds.
In extreme cases this step may have to be repeated.
REPLACING THE CARTRIDGE
1. Shut off the water supply to the faucet.
2. Open the faucet briefly to relieve any pressure
inside the faucet.
3. Move the faucet handles to the “OFF” position.
5. Disconnect supply lines from angle wall valves
and from diverting tee.
6. Use an adjustable wrench to untighten bottom valve
body.
7. Remove cartridge from valve body seat.
8. Install the new cartridges into valve body.
13. Re-assemble faucet in reverse order.
14. Test for leakage.
GENERAL MAINTENANCE
Clean aerator periodically.
Do not use harsh detergents, solvents, chemical agents, metallic sponges, etc. that could
harm the surface and damage the finish.
Clean only with a soft sponge and soapy water.
REQUIRED TOOLS:
17mm Socket Wrench
3/4” Wrench
14. Connect and tighten shorter supply hoses onto diverter-tee. Use open end wrench.
15. Next, install the sidespray assembly by installing rubber gasket & escutcheon
flange along with base shank into 1-3/8” mounting hole.
16. From underneath the sink, install plastic mounting nut onto base shank until fully
tightened.
17. Set sidespray into place. Insert spray hose into base.
18. Install and tighten end of hose onto diverter (M15 fitting).
19. Connect the inlet supply lines to the angle stop wall valves. Do not allow the
supply tubes to twist or bend sharply.
20. Open faucet handle - cold side first - by turning handle clockwise. Let the faucet
run on cold for 15 to 30 seconds.
21. Turn off cold side handle.
22. Open faucet handle - hot side second - by turning handle counter-clockwise. Let the
faucet run on hot for 15 to 30 seconds.
23. Open both faucet handles. Let the faucet run for 15 to 30 seconds.
24. Pull sidespray hose out of its base and point the open end towards the sink drain.
25. Let the sidespray run for 15 to 30 seconds. When sidespray is depressed, ensure
spout turns off and turns back on when spray is not in use.
26. Turn faucet off.
27. Check / test for leaks under the cabinet.
Banjo Fitting