Loading ...
Loading ...
Loading ...
ENGLISH
48
17. [Time] 2 (hour/minute/second) (Command: f x)
Adjusts the Time 2 (hour/minute/second) value.
Transmission
(f)(x)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)(Cr)
Data1 00~17: 00 to 23 hours
Data2 00~3B: 00 to 59 minutes
Data3 00~3B: 00 to 59 seconds
* Enter “fx [Set ID] ff” to view the Time 2 (hour/minute/second) settings.
* This function is only available when Time 1 (year/month/day) is set.
Acknowledgement
(x)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(x)
18. [Off Time Schedule] (Command: f c)
Enables/disables the Off Time Schedule.
Transmission
(f)(c)( )(Set ID)( )(Data)(Cr)
Data 00: Off
01: On
Acknowledgement
(c)( )(Set ID)( )(OK/NG)(Data)(x)
19. [On Time Schedule] (Command: f b)
Enables/disables the On Time schedule.
Transmission
(f)(b)( )(Set ID)( )(Data)(Cr)
Data 00: Off
01: On
Acknowledgement
(b)( )(Set ID)( )(OK/NG)(Data)(x)
20. [Off Timer] (Repeat/Time) (Command: f e)
Configures Off Timer (Repeat/Time) settings.
Transmission
(f)(e)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)(Cr)
Data1
1. f1h~f7h (reading data)
F1: Reads the 1st Off Timer data
F2: Reads the 2nd Off Timer data
F3: Reads the 3rd Off Timer data
F4: Reads the 4th Off Timer data
F5: Reads the 5th Off Timer data
F6: Reads the 6th Off Timer data
F7: Reads the 7th Off Timer data
2. e1h~e7h (delete one index), e0h (delete all indexes)
E0: Erases all Off Timer settings
E1: Erases the 1st Off Timer setting
E2: Erases the 2nd Off Timer setting
E3: Erases the 3rd Off Timer setting
E4: Erases the 4th Off Timer setting
E5: Erases the 5th Off Timer setting
E6: Erases the 6th Off Timer setting
E7: Erases the 7th Off Timer setting
3. 01h~0Ch (sets the day of the week for the Off Timer)
01: Once
02: Daily
03: Mon - Fri
04: Mon - Sat
05: Sat - Sun
06: Every Sunday
07: Every Monday
08: Every Tuesday
09: Every Wednesday
0A: Every Thursday
0B: Every Friday
0C: Every Saturday
Data2 00~17: 00 to 23 hours
Data3 00~3B: 00 to 59 minutes
* To read or delete the Off Time Schedule list, [Data2][Data3] must be
set to FFH.
Example 1: fe 01 f1 ff ff reads the first index data in Off Timer.
Example 2: fe 01 e1 ff ff - deletes the first index data from Off Timer.
Example 3: fe 01 04 02 03 - sets Off Timer to 02:03 from Monday to
Saturday.
* This function is only available when Time 1 (year/month/day) and Time
2 (hour/minute/second) are set.
Acknowledgement
(e)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(x)