26
Maintenance
Periodic Maintenance
NOTE: Before making any adjustments or repairs to the
machine, disconnect the power cord from electrical
source
Twice a month, flush a white vinegar solution (One
quart vinegar to two gallons of water) or anti-browning
solution (mixed as directed) through the extractor. This
will prevent build-up of alkaline residue in the system. If
spray jets become clogged, remove the spray tips,
wash them thoroughly, and blow-dry.
NOTE: Do not use pins, wire, etc. to clean nozzles as
this could destroy spray pattern.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked hoses
should be repaired or replaced to eliminate vacuum or
solution pressure loss. If the cable insulation is broken
or frayed, repair or replace it immediately. Do not take
chances with electrical fire or shock.
Daily / Regular Maintenance
1. Empty unused cleaning solution from the solution
tank.
2. Flush pumping system with 4 to 7 liters of clean,
hot water.
3. After each use, rinse tank with fresh water. Periodi-
cally inspect the recovery tank and decontaminate
if necessary, using a Hospital Grade Virucide or a
1-10 bleach to water solution. Waste water should
be disposed of properly.
4. Check for and remove any lint or debris around vac
shoe and deck wheels.
5. Check spray jets for full spray pattern.
Components
1. Brush 6. Solution Strainer
2. Deep Extraction Jets 7. Spray Jet - Interim
3. Debris Tray 8. Vacuum Shoe
4. Float Shut-off 9. Height Adjust Wheels
5. Solution Drain Hose