4.11Finish the installation.
The fireplace is packaged with a three prong plug installed for plug-in convenience. Hard wiring the
fireplace is also an option for any installation.
Electrical Connection
WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire,
electric
shock or injury to persons, the hard wiring must be supplied with a qualified electrician.
WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the
service panel until installation is complete.
a.
Plug in (
the power cord is 6ft(1.8m) long and on the right of the fireplace, you may run the power
cord out of the framed wall opening to an existing outlet or install an outlet on a nearby wall stud
within the wall). If the cord is not long enough to reach the outlet, a grounded extension cord
minimum AWG No. 14 wiring and rated to a minimum or 1875 watts may be used.