1. Modifying brew volumes. To modify a brew vol-
ume, first check that the SET/LOCK switch is in the
“SET” position on the circuit board.
To increase a brew volume, place the ON/OFF
switch in the “ON” position, press and hold the START
switch until three clicks are heard. Release the switch
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third click
causes the volume setting to be aborted and previous
volume setting will remain in memory) Each time the
switch is pressed, two seconds are added to the brew
time period. Allow the brew cycle to finish in order to
verify that the desired volume has been achieved.
To decrease a brew volume, place the ON/OFF
switch in the “ON” position, press and release the
START switch once for every two-second interval
to be removed from the total brew time period; then
immediately press and hold down the START switch
until three clicks are heard. Relase the switch. (Failure
to release the switch within two seconds after the
third click causes the volume setting to be aborted
and previous volume setting will remain in memory).
Allow the brew cycle to finish in order to verify that
the desired volume has been achieved.
2. Setting brew volumes. To set a brew volume,
first check that the SET/LOCK switch is in the “SET”
position on the circuit board. Place the ON/OFF switch
in the “ON” position, press and hold the START switch
until three distinct clicks are heard and then release
the switch. (Failure to release theh switch within two
seconds after the third click causes the volume setting
to be aborted and previous volume setting will remain
in memory.
View the level of the liquid being dispensed. When
the desired level is reached, turn the ON/OFF switch
to “OFF”.
NOTE: Several ounces of water will continue to sy-
BREW TIMER (cont.)(late models)
SERVICE (cont.)
phon from the tank after turning the switch “OFF”.
The brewer remembers this volume and will continue
to brew batches of this size until the volume setting
procedure is repeated.
NOTE: When brewing coffee, volume will decrease
due to absorption by the coffee grounds.
3. Setting programming disable feature. If it be-
comes necessary to prevent anyone from changing
brew time once programmed, you can set the SET/
LOCK switch to the “LOCK” position. This will prevent
any further programming until switch is once again
put into the “SET” position.
BLU wire from TL5 to Start Switch
WHI/GRN wire from TL4 to A on Relay Coil
BLK wire from TL3 to B on Relay Coil
WHI wire from TL2 to J3 Liquid Level Board
WHI/RED wire from TL1 to J2 Liquid Level Board
FIG. 5 DIGITAL TIMER WIRING
P2037