Page 18
Operating
Instructions
BEFORE USING YOUR APPLIANCE
Remove the exterior and interior packing
Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a
malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF but-ton on the remote
control
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE
button until the COOL
indicator light comes on. When the cooling mode is set, the compressor will start in approxi-
mately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to
exhaust out the hot air.
The temperature setting range of this air conditioner is from 62°F / 17°C to 88°F / 30°C. To set the temperature, press the + or - buttons.
This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs
on fan only mode. This saves energy and prolongs the life of the compres-sor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the fan speeds is not very noticeable
when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan
speed settings.
DRY (DEHUMIDIFYING) ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient
temperature and the fan speed is set to LOW. To activate this function mode, press the MODE button until the DRY indicator light is
displayed. Please note that when switching function mode, there will be an approxi-mately 3 minute transition time. In dehumidifying
mode, the exhaust hose does not need to be vented. If the exhaust hose is vented,the room will be cooled as it dehumidifies. To prevent
cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be re-circulated into the room. If room
temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.
NOTE: When using dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the warm air is exhausted to
the outside and cooling within the room may occur. Additionally, if the exhaust hose is not vented, the unit may require more frequent
draining. Also, the air conditioner does not have a humidistat in which a specific humidity level can be set.
AUTOMATIC MODE
When you set the air conditioner in AUTO mode, it will automatically select cooling or fan only operation depending on what
temperature you have selected and the room temperature is close to the unit. The fan speed is automatically selected and cannot be
changed .To operate the unit in Auto mode when the unit is on, press the MODE button until the AUTO indicator light comes on.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE
button until the FAN indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired
fan speed by pressing the FAN button. When using FAN only mode, venting the exhaust hose to the outside is optional.
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled
and disabled.