SEDONA CARE & USE/INSTALLATION
|
23
BEFORE YOU START... continued
The enclosure should have ventilation holes to prevent
gas build-up in the event of a leak. The deck ledges and
counter should be flat and level. (refer to ANSI Z21.58
Standard for Outdoor Cooking Gas Appliances, Section 1.7
Enclosures For Self Contained LP-Gas Supply Systems)
This grill requires that a 120 volt, 60 hertz, 15 amp GFI
certified outlet be installed by a qualified electrician.
CLEARANCE TO COMBUSTIBLES
Minimum clearance from the sides and back of the grill to
adjacent combustible construction below the counter top
surface are 12” from the sides and back.
Dégagement minimal entre les parois latérales et l’arrière
de l’appariel et la construction combustible au-dessous du
panneau supérieur de l’appareil (30 cm à partir des parois
latérales et 30 cm à partir de l’arrière).
Minimum clearance from the sides and back of the grill to
adjacent combustible construction extending above the
counter top surface are 18” from the sides and back.
Dégagement horizontal minimal entre les parois latérales
et l’arrière de l’appariel et la construction verticale
combustible au-dessus de l’appareil (45.7 cm à partir des
parois latérales et 45.7 cm à partir de l’arrière).
Do not use this appliance under overhead combustible
surfaces.
Ne pas utiliser cet appareil sous une surface combustible.
A minimum of 6” of clearance is needed on the left side of
the grill above the counter top for the motor and skewer.
If the grill is to be placed in a combustible enclosure an
approved insulating jacket is necessary. Order model
number LIJ400, LIJ500, LIJ600 or LIJ700 depending on
your grill size.
OVERHEAD PROTECTION AND EXHAUST REMOVAL
Do not install this appliance under any unprotected
overhead combustible construction. If installed under any
combustible construction the cooking area over the grill
must be covered with an exhaust hood. The hood must
provide 3 to 6 inches of overhang on all exposed sides.
The exhaust hood shall provide no less than 1200 CFM for
proper exhaust ventilation. The hood must be approved for
outdoor installation and provided with a dedicated GFCI
protected branch circuit.
REAR HOOD CLEARANCE
A 3" clearance is required behind the grill to allow the front
hood to open.
The grill exhausts combustion products and cooking
greases to the back. Never locate the grill where this
exhaust will be difficult to clean.
When using a Lynx Quick Disconnect device (LQD) and a Lynx Insulating Jacket the flexible hose must not
contact any portion of the firebox section of the grill. It is recommended that the installer use best fitting
practices to hard pipe the connection outside of the insulating jacket through one of the openings in
the insulating jacket. This will locate the hose outside of the unit and prevent contact with hot surfaces.
Overheating the LQD hose can cause separation and gas leaks that pose a potential fire hazard.