Either an interior or exterior blower or in-line blower may be used with this range hood. It must be installed with blower models P12, ILB11,
EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Connect metal ductwork to cap and work
back towards the hood location. Use 2" metal foil duct tape to seal the joints.
Run 3-wire power supply cable to installation location.
For best capture of cooking impurities, the bottom of the hood must be located at a distance of 36" above cooking surface.
M
ODEL P12 DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
1. SELECT BLOWER OPTION, INSTALL DUCTWORK AND ELECTRICAL WIRING
18"
WALL CAP
36" MINIMUM ABOVE
COOKING
SURFACE
16" TO
TOP
OF WOOD
MOUNTING
STRIP
OPTIONAL DECORATIVE
FLUE
OR SOFFIT
HH0185A
ROOF CAP
10" ROUND DUCT
10" ROUND ELBOW
MODEL EB12 OR EB15 EXTERIOR
B
LOWER TYPICAL DUCTWORK
EXTERIOR
BLOWER
EXTERIOR
BLOWER
18"
36" MINIMUM ABOVE
COOKING
SURFACE
16" TO
TOP
OF WOOD
MOUNTING
STRIP
OPTIONAL DECORATIVE
FLUE
OR SOFFIT
HH0183A
10" ROUND DUCT
10" ROUND ELBOW
MODEL ILB11 IN-LINE BLOWER
TYPICAL DUCTWORK
IN-LINE BLOWER
10" ROUND DUCT
HH0184A
36" MINIMUM ABOVE
COOKING
SURFACE
ROOF CAP
WALL
CAP
CAUTION
This range hood is intended for outdoor covered patio or lanai area. As with all electric appliances, this unit must
be protected from the effects of weather.
WARNING
!
This range hood is not designed for use with a charcoal grill.
WARNING
!
The power cable must be a GFCI protected branch circuit.