Installation
Electrical Connection
5
Before proceeding further, verify that the
power supply is disconnected. Verify that
the appropriate electrical supply requirements
have been met. Please refer to the table on
page 12 for appropriate electrical require-
ments. The cooktop is supplied with a 36-inch
long conduit for a connection to an accessible
junction box. The 240V conduit consists of
three insulated wires. There are two
insulated hot lead conductors (red and black)
and one insulated ground conductor (green).
The 120V conduit consists of three insulated
wires. There is the hot lead conductor (black),
the neutral conductor (white) and one
insulated ground conductor (green).
Attach conductor wires to residence wiring in
accordance with national, state and local
electric codes.
WARNING!
The entire appliance must be grounded
at all times when the electrical power
supply is on. Do not ground the
appliance with the neutral house supply
wire (white). A separate ground must
be used.
6
Remove the plastic lm from the cooktop.
Clean the cooktop before you use it for the
rst time. A thorough cleaning with a
recommended cooktop cleaner (Cerama
Bryte Ceramic Cooktop Cleaner) will provide
a clean, shiny coating on the cooktop surface.