User Manual - Page 24

For 0603672100.

Loading ...
Loading ...
Loading ...
24 | English
Technical Data
Digital laser measure PLR 30 C PLR 40 C
Article number
3 603 F72 1.. 3 603 F72 3..
Measuring range 0.05–30 m
A)
0.05–40 m
A)
Measuring accuracy (typical) ±2.0 mm
B)
±2.0 mm
B)
Smallest display unit 1 mm 1 mm
Operating temperature -10 °C to +40 °C -10 °C to +40 °C
Storage temperature -20 °C to +70 °C -20 °C to +70 °C
Relative air humidity max. 90% 90%
Max. altitude 2000 m 2000 m
Pollution degree according to IEC61010-1 2
C)
2
C)
Laser class 2 2
Laser type 635 nm, < 1mW 635 nm, < 1mW
Laser beam diameter
D)
(at 25 °C) at ap-
prox.
10m distance 9mm 9mm
30m distance 27mm 27mm
40m distance 36mm
Automatic switch-off after approx.
Laser 20 s 20 s
Measuring tool (without measurement) 5 min 5 min
Bluetooth® (if inactive) 3 min 3 min
Weight according to EPTA-Procedure
01:2014
0.084 kg 0.084 kg
Dimensions 100 x 42 x 22 mm 100 x 42 x 22 mm
Batteries 2 x 1.5 V LR03
(AAA)
2 x 1.5 V LR03
(AAA)
Battery life approx.
Individual measurements 10,000
E)F)
10,000
E)F)
Continuous measurement 2.5 h
E)F)
2.5 h
E)F)
Data transmission
1 609 92A 4P0 | (18.01.2019) Bosch Power Tools