TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Log set produces a
clicking/ticking noise
just after burner is lit
or shut off.
1. Metal expanding while
heating or contracting while
cooling.
1. This is common with most log sets. If
noise is excessive, contact qualied
service person.
Log set produces
unwanted odors.
1. Log Set burning vapors
from paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See IMPORTANT
statement page 19).
2. Gas leak. See Warning
statement page 19.
1. Open ue to maximum. Stop using odor
causing products while log set is running.
2. Locate and correct all leaks (see Check-
ing Gas Connections, page 10).
Gas odor even
when control knob is
in OFF position.
1. Gas leak. See Warning
statement page 19.
2. Control valve defective.
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 10).
2. Replace control valve.
Gas odor during
combustion.
1. Gas leak. See Warning
statement at top of page 19.
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 10).
Whistle noise when
burner is on.
1. Air in gas line.
2. Control knob not in fully
open position.
3. Spiral gas ex line.
1. Bleed gas lines.
2. Turn control to full Open position.
3. Replace gas supply line.