Leviton IPV15-1LZ Decora Vacancy Motion Sensor In-Wall Switch, Manual-On, 15A, Single Pole or 3-Way, White/Ivory/Light Almond

INSTALLATION INSTRUCTIONS - Page 2

For IPV15-1LZ.

PDF File Manual, 2 pages, Read Online | Download pdf file

IPV15-1LZ photo
Loading ...
•Positionallwirestoprovideroominoutletwallbox
fordevice.
•Ensurethattheword"TOP"isfacingupondevice
strap.
•Partially screw in mounting screws in wall box
mounting holes.
•Removethefacecoverofthesensortoexpose
the adjustment dials (refer to Changing the
Color of your Device on page 1).
•Settimeselectionofthesensorto30seconds
foraquicktimeoutduringtesting(Refer to
ADJUSTMENT SETTINGS section).
•Setthelightleveldialfullclockwise(Refer to ADJUSTMENT SETTINGS
section).
•Placethefacecoverbackonthesensor.
•Restorepoweratcircuitbreakerorfuse.
•ForIPS15lightswillautomaticallyturnonafterpowerisapplied.
•ForIPV15,pressandreleasepushpadtoturnthelightsON.
NOTE: See Locator Light Status chart to confirm the operational state of
thedevice.IflightsstilldonotturnON,refertotheTROUBLESHOOTING
section.
•Leavetheroomoreldofviewtoallowthesensortotimeoutandshutoff
the lights due to absence of motion.
•Within30secondsofthelightstimingoutstepbackintotheroomorthe
eldofviewofthesensorandthelightsshouldturnbackonautomatically.
•Ifthelightsdonotturnoff30secondsafterleavingtheroomdecreasethe
sensitivityofthesensor(refer to the ADJUSTMENT SETTING section).
•Ifthelightstonotturnbackonautomaticallywhenyoustepbackintothe
roomincreasethesensitivityofthesensor(refer to the ADJUSTMENT
SETTING section).
•Settimeselectionandlightlevel(Refer to ADJUSTMENT SETTINGS
section).
•Whenthedesiredlightlevel(IPS15 only),timeselectionandsensitivity
settingsareselectedplacethefacecoverbackonthesensorand
continue to Step 6.
Restore Power: Restore power at circuit breaker or
fuse.
Installation is complete.
Step 7
Device Mounting:
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Step 6
Installation may now be
completed by tightening
mounting screws into wall
box. Attach wallplate.
Testing your Device prior to mounting in wall box:
Step 5
NOTE: Dress wires with a bend as shown in diagram in order
torelievestresswhenmountingdevice.
ADJUSTMENT SETTINGS
NOTE: Toavoid PERMANENT DAMAGE to the unit, be careful NOT TO
OVERTURN the adjustment dials when setting the Sensor.
1. Withpowerrestoredandwallplateremoved,removefaceofdevicetoexpose
adjustment dials (refer to Changing the Color of your Device on page 1).
Useasmallscrewdrivertoadjustthelightlevel,timeselectionandsensitivity
onthedeviceasfollows (Refer to Diagram):
Light Level Adjustment (IPS15 only):
Adjustthelightleveldialclockwise.LightswillturnONinlighterconditions.
Adjustthelightleveldialcounterclockwise.LightswillturnONinlesslighting
conditions.
Time Selection:
•Adjustthetimeselectordialtothedesiredlengthoftimethelightsareto
remainON.LightswillremainONfrom30secondsto30minutesafterthe
roomisvacated.
•AdjustthetimeselectordialclockwisetoincreasethedurationoftheON
timeupto30minutes.
•Adjustthetimeselectordialcounterclockwisetodecreasethedurationofthe
ONtimedownto30sec.
Sensitivity:
•Increaseordecreasethesensitivityofthesensorasfollows.
•Todecreasesensitivityanddetectionrange,rotatethedialcounter-clockwise.
Toincreasethesensitivityanddetectionrange,rotatethedialclockwise.With
thearrowpointingat3thesensitivityisfull.Withthearrowpointingat0,the
sensitivityisreducedbyhalf.Asthedialrotatesfrom2to0,thechangein
sensitivityismadeinnesteps.
2. Attachthefacecoverandtestthatthelightlevel,timeselectionand
sensitivityaresetasdesired.Ifnot,repeatadjustmentsuntilsatised.
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
ThisproductiscoveredbyU.S.Pat.No.7,924,155
and corresponding foreign patents.
©2012LevitonManufacturingCo.,Inc.
AllRightsIncludingTradeDressRightsReserved
TROUBLESHOOTING
Lights do not switch ON - IPS15:
• Motionisbeyondsensingrange,moveclosertoswitch.
• Adjustthelightleveladjustmenttowardlighterordarker,dependingon
room conditions.
Lights always stay ON:
• ChecktimedelaysettingsandcomparetohowlongthelightsstayON.
• Besurethatnomotionoccursincoverageareafortimeselected.
• Checkthatswitchisnotinstallednearaheatsource(e.g.,stove,lights,
heatvents)ordetectingmotionfromanadjacentarea(e.g.,hallway
trafc).Ifso,switchmayhavetoberelocated.
•
TryloweringtheSensitivityAdjustmentControl.Rotatetheknob
counterclockwiseabout30°.Iftheproblempersists,tryreducingagain.
NOTE: DO NOT reduce so much that the sensor cannot see normal
occupancy.
Lights do not turn ON with the pushpad - IPV15:
• Checkthatswitchisinstalledcorrectly.
• CheckthatpowerisON.
• Checkthatlightbulbisfunctioning.
NOTE: If problems continue, consult an electrician.
FCC COMPLIANCE STATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubject
tofollowingtwoconditions:(1)thisdevicemaynotcauseharmful
interference,and(2)thisdevicemustacceptanyinterferencereceived,
includinginterferencethatmaycauseundesiredoperationofthedevice.
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfor
aClassBDigitalDevice,pursuanttoPart15oftheFCCRules.These
limitsaredesignedtoprovidereasonableprotectionagainstharmful
interferenceinaresidentialinstallation.Thisequipmentgenerates,uses,
andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin
accordance with the instructions, may cause harmful interference to radio
communications.However,thereisnoguaranteethatinterferencewill
notoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful
interferencetoradioortelevisionreception,whichcanbedetermined
byturningtheequipmentOFFandON,theuserisencouragedtotryto
correct the interference by one or more of the following measures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthatto
whichthereceiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION
AnychangesormodicationsnotexpresslyapprovedbyLeviton
ManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatethe
equipment.
LOCATOR LIGHT STATUS
LOAD
IPS15 IPV15
OFF
Blinking Lit
ON
Blinking Blinking
Lens
Push
Pad
Locator
Light
Side (Vertical) Field-of-View
SENSING AREA COVERAGE
Field-of-View (Horizontal)
9.1m
30ft
9.1m
6ft
1.7m
1.8m
6ft
30ft
9.1m
8.4m
27ft
2.1m
7ft
1.2m
4ft
2.6m
8ft
Light Level
Adjustment
Sensitivity
Adjustment
Time
Selection
1 2
0 3
1 2
0 3
1 2
0 3
Settings
0
1
2
3
Time
30sec
5 min
15 min
30min
PK-93977-10-00-2A©2012LevitonMfg.Co.,Inc.
NOTE:TheOccupancysensormust be installed in a wall box that
hasaLoadconnection.TheSensorremotemust be installed in a
wallboxwithaLineHotconnectionandaNeutralconnection.A
Neutralwiretotheremoteneedstobeaddedasshown.Ifyouare
unsure about any part of these instructions, consult an electrician.
NOTE: Maximum wire length from sensor to all installed remotes
cannotexceed300ft(90m).
WIRING REMOTE
(wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
•GreenorbarecopperwireinwallboxtoGreenterminalscrew.
•LineHot(common)wallboxwireidentied(tagged)when
removingoldswitchandFirstTravelertosensorterminalscrew
marked "BK".
•SecondTravelerwallboxwirefromsensortoremoteterminalscrew
marked"3-Way"(note wire color).Thistravelerfromtheremote
mustgototheterminalscrewonthesensormarked"3-Way".
•Neutralwallboxwiretoremoteterminalscrewmarked"WH".
WIRING SENSOR (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
•GreenorbarecopperwireinwallboxtoGreenterminalscrew.
•Loadwallboxwireidentied(tagged)whenremovingoldswitchto
terminal screw marked "RD".
•FirstTravelerLineHottoterminalscrewmarked"BK".
•RemoveRedinsulatinglabelfromterminalscrewmarked"3-Way".
•SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"3-Way".Thistravelerfromthesensormustgotothe
terminalscrewontheremotemarked"3-Way".
•Neutralwallboxwiretoremoteterminalscrewmarked"WH".
•ProceedtoStep5.
3-Way Wiring with Sensor Remote or Vizia
TM
Matching Remote (w/LED) Application:
NOTE: IPV0R sensor remote is depicted.
Additional
Neutral Wire
Terminal
Screw marked
Black (BK)
Brass Terminal
Screw marked
3-Way
BK
WH
RD
3-Way
3
5
1
4
2
BK
WH
RD
3-Way
3
2
1
4
5
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
White (WH)
SensorIPV0R/VP0SR-1L Remote
Ground
Terminal Screw
(Green)
Hot (Bla c k )
Neutral (White)
Sensor IPV0R/VP0SR-1L Remote
3-Way
RD 3-Way
WH
BK BK
Bla c k
White
Line
120 V A C , 60H z
WH
Load
Green
Ground
Green
Ground
C
OPERATION
IPS15
Auto ON: LightswillautomaticallyturnONwhenroomisoccupiedormotion
isdetected.TheIPS15willswitchlightsOFFwhennomotionisdetectedin
un-occupied room after set period of time.
Time delay adjustment: Refer to section on Adjustment Settings.
Manual ON:TheIPS15willmanuallyturn-onlightsortheloadbydepressing
thepushpadonthedevice.TheIPS15canbesettoonlyturnONbythe
pushpad(noautomaticonoperation)byadjustingtheambientlightcontrolto
the "0" position.
IPV15
Manual ON:
TheIPV15requirestheusertomanuallyturnONlightsortheload
by depressing the
push pad
onthedevice.Thelightsorloadwillautomatically
turn-off when the room is left unoccupied for a set period of time.
Time delay adjustment: Refer to section on Adjustment Settings.
NOTE:
Ina3-wayapplication,usingvizia
TM
matching or coordinating remotes,
theremotewillonlyhavetheabilitytomanuallyswitchtheloadON,thesensor
willthentimeoutandswitchtheloadOFFoncemotionisnolongerdetected.
For automatic control at both locations, use IPV0R as the remote.
Locator Light LED:
IPS15:LEDblinkswhenmotionisdetectedandiftheloadisONorOFF.
IPV15: LEDblinkswhenmotionisdetectedandwhenloadisON.LEDwill
remainilluminatedwhenloadisOFF.