Model: VIBE100TWS
Driver Size: 8 mm / 0.31” Dynamic Driver
Power supply: 5 V 1 A
Weight: 46.3 g / 0.102 lbs
Earpiece: 5.1 g / 0.011 lbs (10.2 g / 0.022 lbs combined )
Charging case: 36.1 g / 0.08 lbs
Headset battery type: Lithium-ion Battery (45 mAh / 3.7 V)
Charging case battery type: Lithium-ion Battery (550 mAh / 3.7 V)
Charging time: 2 hrs from empty
Music playtime with BT on: up to 5 hrs
Frequency Response: 20 Hz – 20 kHz
Impedance: 16 ohm
Sensitivity: 105.5 dB SPL@1kHz
Maximum SPL: 94 dB
Microphone sensitivity: -11.3 dBV@1 kHz / Pa
Bluetooth version: 5.0
Bluetooth profile version: A2DP V1.3 AVRCP V1.6 HFP V1.7
Bluetooth transmitter frequency range: 2.4 - 2.4835 GHz
Bluetooth transmitter power: < 10 dBm
Bluetooth transmitter modulation: GFSK, π/4-DQPSK, 8-DPSK
Maximum operation temperature: 45°C
IC RF Exposure Information and Statement
The SAR limit of Canada (C) is 1.6 W/kg averaged over one gram of tissue. Device types: (IC: 6132A-JBLV100TWS) has also been tested against this SAR limit According to this standard, the highest SAR value reported during product certification for head use is 0.59W/kg.The device was tested for typical bodily operations where the product was kept 0 mm from the head. To maintain compliance with IC RF exposure requirements, use accessories that maintain a separation distance of 0mm between the user›s head and the back of the headset. The use of belt clips, holsters and similar accessories shall not contain metal parts in its assembly. Use of accessories that do not meet these requirements may not comply with IC RF exposure requirements and should be avoided.
Head operation
The device was subjected to a typical head manipulation test. In order to comply with RF exposure requirements, a minimum separation distance of 0 cm must be maintained between the user›s ear and the product (including the antenna). Head exposure that do not meet these requirements may not meet RF exposure requirements and should be avoided. Use only the supplied or approved antenna. IC: 6132A-JBLV100TWS