NAPOLI PIZZA OVENS CARE & USE/INSTALLATION
BUILT-IN INSTALLATIONS
The Lynx Built-In oven is designed for easy installation into
masonry enclosures.
NOTE: Lynx pizza ovens are intended for installation
in a built in masonry enclosure or mounted to a non-
combustible counter or the optional LPZAF freestanding
cart.
For built-in applications the oven drops into the opening
shown in the specifications and installation details drawing.
A deck is required to support the oven from the bottom.
The enclosure should have ventilation holes to prevent LP
gas build-up in the event of a leak. The deck ledges and
counter should be flat and level. (refer to ANSI Z21.58
Standard for Outdoor Cooking Gas Appliances, Section 1.7
Enclosures For Self Contained LP-Gas Supply Systems)
This oven requires that a 120 volt, 60 hertz, 15 amp GFI
certified outlet be installed by a qualified electrician.
CLEARANCE TO COMBUSTIBLE MATERIALS
Minimum clearance from the sides and back of the oven to
adjacent combustible construction below the top of unit are
0” from the sides and back.
Dégagement minimal entre les parois latérales et
l’arrière de l’appariel et la construction combustible
au-dessous du panneau supérieur de l’appareil (0 cm à
partir des parois latérales et 0 cm à partir de l’arrière).
Minimum clearance from sides and back of unit to adjacent
combustible construction extending above the unit is 18”
from the sides and back.
Dégagement horizontal minimal entre les parois
latérales et l’arrière de l’appariel et la construction
verticale combustible au-dessus de l’appareil (45.7
cm à partir des parois latérales et 45.7 cm à partir de
l’arrière).
Do not use this appliance under unprotected overhead
combustible surfaces.
Ne pas utiliser cet appareil en-dessous de surfaces
combustibles non protégées.
OVERHEAD PROTECTION AND EXHAUST REMOVAL
Do not install this appliance under any unprotected
overhead combustible construction. If installed under any
combustible construction the cooking area over the oven
must be covered with an exhaust hood. The hood must
provide 3 to 6 inches of overhang on all exposed sides.
The exhaust hood shall provide no less than 1200 CFM for
proper exhaust ventilation. The hood must be approved for
outdoor installation and provided with a dedicated GFCI
protected branch circuit.
BEFORE YOU START ...continued