Networked operation
Several appliances can be networked together. The light
and blower on each of the appliances are operated
synchronously.
Connect the appliances in series via the connector
sockets X1and X2(equal value). The sequence of the
networking does not have any effect. If the enclosed
network cables are too short, use a commercially
available network cable (min. Cat. 5, shielded).
Maximum number of networked appliances: 20. Total
length of all of the network cables: 131 feet (40 m).
During the initial installation, a qualified electrician
must check that the system functions correctly.
If one of the networked appliances fails (power
interruption, network cable disconnected), this leads to
the blower function being blocked for the entire system.
All of the buttons on the appliance flash.
When changing the configuration, the system must be
re-initialized:
1 Unscrew the cover plate.
2 Press and hold the reset button until both LEDs
light up continuously (approx. 5seconds). Then
release the button within 5seconds.
3 Screw on the cover plate.
4 After initialization, have a qualified electrician
check that the system functions correctly.
Connect Electrical Supply
9 WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during
installation.
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must conform to the requirements of
the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
This appliance is connected with a plug
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
The appliance must be properly grounded.
Plug must be rated not less than type 6-20 P (2-pole
3-wire grounding).
Only a qualified electrician should connect the
plug.
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still
be accessible after installation.
Removing appliance
Disconnect the appliance from the power supply. For
flush-mounted appliances, remove the silicone joint.
Push out the appliance from below.
9 CAUTION
Damage to appliance! Don't lever device out from
above at the frame.
;
;
;
;