Leviton IPS06-1LW Refrigeration

Installation Instructions - Page 2

For IPS06-1LW. Also, The document are for others Leviton models: LTM268W, LTM268S

PDF File Manual, 2 pages, Read Online | Download pdf file

IPS06-1LW photo
Loading ...
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Levitonwarrants to theoriginal consumerpurchaser and notforthe benet ofanyoneelsethat thisproductat thetime of itssale by Levitonis freeof defectsin materials and workmanshipunder normal andproperuse forveyearsfrom thepurchase date. Leviton’s only obligationisto correct suchdefectsbyrepair or replacement,at its option,if withinsuch veyearperiod theproduct isreturned prepaid,with
proofofpurchase date, and adescription oftheproblemto Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.Thiswarrantyexcludesand thereisdisclaimed liability forlabor forremovalofthis product orreinstallation.Thiswarrantyisvoidifthis product isinstalledimproperly orinan improperenvironment,overloaded,misused, opened,
abused,or altered in any manner,or is not used under normal operating conditions or not in accordance with any labels or instructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, butif any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and tness for
a particular purpose, is limited to veyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.The remedies provided hereinare the exclusiveremedies underthis warranty, whether based on contract, tort or otherwise.
PK-93978-10-00-2A
©2012LevitonMfg.Co.,Inc.
Positionallwirestoprovideroominoutletwallboxfordevice.
• Ensurethattheword"TOP"isfacingupondevicestrap.
• Partiallyscrewinmountingscrewsinwallboxmountingholes.
• Restorepoweratcircuitbreakerorfuse.
• ForIPS06lightswillautomaticallyturnON
afterpowerisapplied.
• ForIPV06pressamdreleasepushpadto
turnthelightsON.
See Locator Light Status chart to
confirm the operational state of the
device.
If lights still do not turn ON, refer to the
TROUBLESHOOTING section.
Testing your Device prior to mounting in
wall box:
Step 5
Restore Power:Restorepoweratcircuitbreaker
orfuse.
Installation is complete.
Step 7
Device Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE.
Step 6
Installationmaynowbecompletedbytighteningmountingscrews
intowallbox.Attachwallplate.
OPERATION
Locator Light LED:
IPS06:
LEDblinkswhenmotionisdetectedandiftheloadisONorOFF.
IPV06: LEDblinkswhenmotionisdetectedandwhenloadisON.
LEDwillremainilluminatedwhenloadisOFF.
NOTE: Dresswireswithabendas
shownindiagraminordertorelieve
stresswhenmountingdevice.
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
ThisproductiscoveredbyU.S.Pat.No.7,924,155
andcorrespondingforeignpatents.
©2012LevitonManufacturingCo.,Inc.
AllRightsIncludingTradeDressRightsReserved
TROUBLESHOOTING
Lights do not switch ON - IPS06:
• Motionisbeyondsensingrange,moveclosertoswitch.
• Adjustthelightleveladjustmenttowardlighterordarker,
dependingonroomconditions.
Lights always stay ON:
• Checktimedelaysettingsandcomparetohowlongthelights
stayON.
• Besurethatnomotionoccursincoverageareafortime
selected.
• Checkthatswitchisnotinstallednearaheatsource(e.g.,stove,
lights,heatvents)ordetectingmotionfromanadjacentarea
(e.g.,hallwaytrafc).Ifso,switchmayhavetoberelocated.
Lights do not turn ON - IPV06:
• Checkthatswitchisinstalledcorrectly.
• CheckthatpowerisON.
• Checkthatlightbulbisfunctioning.
NOTE:Ifproblemscontinue,consultanelectrician.
ADJUSTMENT SETTINGS
1. Withpowerrestoredandwallplateremoved,removefaceof
devicetoexposesettingcontrols,seecolorchangeinstructionsin
page1.Useasmallscrewdrivertoadjustthelightsensitivityand
timesettingsonthedeviceasfollows:
Light Level Adjustment:
•Adjustthelightleveldialclockwise.LightswillturnONinlighter
conditions.
•Adjustthelightleveldialcounterclockwise.LightswillturnON
inlesslightingconditions.
•Adjustinglightlevelfullycounterclockwisewillrequiremanual
operationofthesensor.
Time Selection:
• Adjustthetimeselectordialtothedesiredlengthoftimethe
lightsaretoremainON.LightswillremainONfrom30seconds
to30minutesaftertheroomisvacated.
• Adjustthetimeselectordialclockwisetoincreasetheduration
oftheONtimeupto30minutes.
• Adjustthetimeselectordialcounterclockwisetodecreasethe
durationoftheONtimedownto30sec.
2. Testthatthelightlevelandtimeselectionareasdesired.
Ifnot,repeatadjustmentsuntilsatised.
3. Mountwallplate.INSTALLATION IS COMPLETE.
IPS06
Auto On: LightswillautomaticallyturnONwhenroomisoccupiedor
motionisdetected.TheIPS06willswitchlightsOFFwhennomotion
isdetectedinun-occupiedroomaftersetperiodoftime.
Time delay adjustment:RefertosectiononAdjustmentSettings.
Light level adjustment:RefertosectiononAdjustmentsettings.
Manual ON: TheIPS06willmanuallyturnONlightsortheloadby
depressingthepushpadonthedevice.
IPV06
Manual ON:TheIPV06requirestheusertomanuallyturnONlights
ortheloadbydepressingthepushpadonthedevice.
ThelightsorloadwillautomaticallyturnOFFwhentheroomisleft
un-occupiedforasetperiodoftime.
TheIPV06canalsobeturnedoffmanuallybydepressingthe
pushpad.
Time delay adjustment:refertosectiononAdjustmentsettings
Light Level
Adjustment
Time Selection
1 2
0 3
1 2
0 3
Settings Time
0 30Sec
1 5Min
2 15Min
3 30Min
Push
Pad
LOCATOR LIGHT STATUS
LOAD
IPS06 IPV06
OFF
Blinking Lit
ON
Blinking Blinking
NOTE:Ina3-wayapplication,the3wayswitchprovidestheabilityto
manuallyswitchtheloadONfromasecondlocation.Thesensorwill
timeoutandswitchtheloadOFFoncemotionisnolongerdetected
andthetimedelayexpires.
SENSING AREA COVERAGE
Field-of-View (Horizontal)
Side (Vertical) Field-of-View
1.5m
5ft
30ft
9.1m
30ft
9.1m
6ft
1.7m
1.8m
6ft
5ft
1.5m
30ft
9.1m
1.4m
4ft
8.4m
27ft
2.1m
7ft
1.5m
5ft
1.2m
4ft
1.7m
6ft
2.6m
8ft
Locator
Light
Lens
FCC COMPLIANCE STATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjectto
followingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,
and(2)thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperationofthedevice.
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfora
ClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimits
aredesignedtoprovidereasonableprotectionagainstharmfulinterference
inaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiate
radiofrequencyenergyand,ifnotinstalledandusedinaccordancewith
theinstructions,maycauseharmfulinterferencetoradiocommunications.
However,thereisnoguaranteethatinterferencewillnotoccurinaparticular
installation.Ifthisequipmentdoescauseharmfulinterferencetoradioor
televisionreception,whichcanbedeterminedbyturningtheequipmentOFF
andON,theuserisencouragedtotrytocorrecttheinterferencebyoneor
moreofthefollowingmeasures:
•ReorientorrelocatethereceivingAntenna.
•Increasetheseparationbetweentheequipmentandthereceiver.
•Connecttheequipmentintoanoutletonacircuitdifferentfromthatto
whichthereceiverisconnected.
•Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION
AnychangesormodicationsnotexpresslyapprovedbyLeviton
ManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatethe
equipment.
NOTE: TooperatetheIPS06asavacancysensor(manualON/Auto
OFF)-rotatethelightleveladjustmentfullycounterclockwise.
FOR CANADA ONLY
Forwarrantyinformationand/orproductreturns,residents
ofCanadashouldcontactLevitoninwritingatLeviton
Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire
(Quebec), Canada H9R 1E9orbytelephoneat1 800 405-5320.