User Manual SereneLife SLPAC8 8,000 BTU Portable Air Conditioner Compact Home AC Cooling Unit

SereneLife SLPAC8 8,000 BTU Portable Air Conditioner Compact Home AC Cooling Unit - Use Manual - Use Guide PDF.
Documents: Go to download!
User Manual
  • User Manual - (English)
Specification


Owner's Guide Air Conditioners

Product Introduction

MAIN PARTS AND COMPONENTS

  1. Handle
  2. Control panel
  3. Louver
  4. Caster
  5. Air outlet
  6. Air inlet
  7. Drainage nozzle
  8. Remote controller
  9. Exhaust duct assembly
  10. Window sealing plate assembly

Control Panel and Remote Controller

  1. Power key
    Press the key to turn ON/OFF the A/C.
  2. Mode key
    Press the key to choose cool, fan and dry.
  3. Temperature/ time adjusting key
    Press the key at cooling mode to increase/ reduce the setting temperature; press it at timing mode to adjust time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature.
  4. Speed key
    Press the key to choose high/ low spee d.
  5. Timer key
    Press the key at standby mode to set ON time. Press this key at ON mode to set OFF time.
  6. Temperature/ Time Display Window

    See other models: PUCRC25.5 PUCRC96B SLTLSP01 PSLMRB2 PSLMRP15
    Displays the adjusted temperature and time
  7. Remote controller receiving window
    It is used to receive signal of the remote controller.
  8. °C/°F switching key
    Press the key to switch °C and °F
  9. Sleep key
    In the cooling mode, the sleep mode can be selected by this key

OPERATION METHOD

Cooling Mode

  • When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.
  • Press Up/Down key to adjust setting temperature (16°C~30°C)(60°F~86°F).
  • Press Speed key to choose High/Mid/Low speed.

Fan Mode

  • When pressing mode key or choosing Fan mode by pressing the remote controller, the wind indicator lamp lights up.
  • Press Speed key to choose High/Mid/Low speed.
  • Temperature can’t be set.

Dehumidification Mode

  • When pressing mode key or choosing dehumidification mode by pressing the remote controller, the dehumidification indicator lamp lights up.
  • Remove the dehumidification water wedge, insert water manifold, place the other end of the water manifold into the water vessel or drainage passage, as shown in the right figure.
  • After entering the dehumidification mode, if room tempearture≥17°C (62°F), the compressor is ON. Then control as follows: when room temperature ≤15°C (59°F), the compressor is OFF; when temperature increases to room temperature≥17°C (62°F), the compressor will start again (in order to protect the compressor, it will be restarted 3min. later).
  • In dehumidification mode, the fan is defaulted to run at low speed, and wind speed can’t be adjusted.
  • Temperature can’t be set.

Note : When use dehumidify function, should remove exit pipe components, otherwise, it will cause worse dehumidify performance, and appear “FL” water full alarm

Sleep mode (optional function)

  • Under cool mode, pressing sleep mode key on the remote controller or pressing time key and down key together on the machine, it will start sleep mode with low wind speed and can’t be adjusted. Pressing the sleep mode key again or pressing time key and down k ey together on the machine to quit the sleep mode.
  • If you press the wind speed key under the sleep mode, the screen will display ”SL”

Timer Mode

  • In standby state, press the Timer key to set ON time. Press Up and Down keys to set ON time (0~24H), and the timer indicator lamp lights up.
  • In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (0~24H), and the timer indicator lamp lights up.

Clean and Maintenance

DRAINAGE METHOD

This product is equipped with automatic water vaporization system. The condenser is cooled with the circulating of condensing water, so as to improve cooling efficiency and save energy.

  • If the internal vessel is full of water, the display screen will display “FL”, and the compressor stops working automatically. After power off, unscrew the water cover, pull out the water plug to drain off water, and it will become normal after being restarted.

MAINTENANCE

Notice: In order to avoid electric shock, please turn off the A/C and unplug before maintenance or repair.

CLEANING

  • Unplug before cleaning.
  • Wipe with soft semi-dry cloth. Don’t use chemical reagent, such as benzene, alcohol and gasoline etc; otherwise surface of the A/C and even the whole A/C will be damaged.
  • Prevent water from spattering in the A/C.

FILTER SCREEN

  • Wash the filter screen once every two weeks. If it is blocked by dust, efficiency of the A/C will be reduced.
  • Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures.
  • Put the filter screen into the warm water (about 40°C or 104°F) added with neutral detergent, dry it at a shady place after cleaning.

SEASONAL CLEANING

If the A/C will not be used for a long time:

  • Pull out the water plug to drain.
  • Run the A/C in fan mode for 2H till the inside is dry.
  • Turn off the A/C and unplug.
  • Wash the filter screen and reassemble it.
  • Dismantle the exhaust duct and keep it properly.
  • Cover the A/C with a plastic bag and place it at a dry place.

Common Failures and Diagnosis

Intelligent Error Detection

Error-detecting code

Multi-functional defection

E1

Error of the coil’s temperature sensor

E2

Error of indoor temperature sensor

E4

Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature excesses 8°C or 46.4°F, the protection is released and previous working state is recovered.

Troubleshooting

In case of any of the following trouble, please contact professional maintenance personnel in time.

TROUBLE

CAUSE

SOLUTION

The A/C doesn’t work

No display

Reset circuit breaker on AC cord

The display panel displays “FL”

Restart the A/C after power off and draining, then it will become normal

Time OFF function is started

The A/C can be restarted 3 minutes after being turning off.

The A/C starts frequently

Direct sunlight

Draw the curtain

Doors and windows keep open; there are lots of people or heat source in room

Close doors and windows, remove heat source

Filter screen is very dirty

Clean or replace it

Air inlet or air outlet is blocked

Remove the stem

Big noise of the A/C

The A/C is placed unevenly

Place it at even and firm ground, avoid shaking

The compressor doesn’t work

Its delay protection is started

Wait for 3min., turn on after temperature decreases

Notice: When there is any abnormal to the A/C, turn it off and unplug, and then contact professional maintenance personnel.

The above technical parameters are subject to change without notice.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well -being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge.


SereneLife SLPAC8 | File type: PDF | Filename: 77198109_slpac8.pdf | Size: 4.01 MB | Language: English

Download User Manual

Specs Sheet

  • Capacity: 1800 Cubic Feet
  • Product Dimensions: 13.8"D x 14.6"W x 27.2"H
  • Item Weight: 46.3 pounds
  • Cable Length: 12 Feet
  • Cooling Power: 8000 British Thermal Units
  • Voltage: 120
  • Special Feature: Portable, Remote Control, Dehumidifier
  • Seasonal Energy Efficiency Ratio: 9.8
  • Noise Level: 55 dB
  • Floor Area: 200 Square Feet
  • Color: White

Product Infomation and Reviews - SLPAC8 photo

SLPAC8 Photo

T: @manualsFile

https://manualsFile.com

SereneLife SLPAC8 Questions and Answers