5. Remove the hood from its packaging and place the back of the hood on the floor or countertop
in front of the wall where it will hang.
6. With the hood on its back facing you, remove the blower shield(s) and blower housing(s) as
follows:
a) Remove the shipping tape that is securing the blower shield(s) inside the hood.
b) Remove the blower shield(s) by lightly pulling it toward the front of the hood.
c) Gently close the back draft damper(s) from the top side of the hood.
d) To remove the blower housing(s), unsnap the suitcase latches (one on each side of the
housing).
e) Support the housing and lift it away from the blower base, then tip it back toward you to
clear the blower wheel(s), and then pull it from the hood.
Make sure power is off at the supply panel / breaker during service or
installation.
7. One blower motor must be removed from each blower assembly to access the connection
box(es). The blower assembly will have a decal identifying the location of the connection
box(es). It is not necessary to remove the blower wheel from the motor.
a) Remove the three screws retaining the blower motor.
b) Pull the motor out far enough so you can reach its electrical connector.
c) Unplug the connector, set the blower motor and screws aside.
8" Round
Connection Diagram (42” width)
WM2L Dual + WM1L Single Blower (900 CFM) (Top View)
(Wall Side)
Centerline
of hood
Electrical (2)
Motor
Cooling
Vent (3)
6" [15.2 cm]
Round
7-5/16"
[18.6 cm]
1-7/8"
[4.8 cm]
5-1/4"
[13.3 cm]
1-3/4"
[4.4 cm]
7-5/16"
[18.6 cm]
5-1/2"
[14 cm]
Electrical (2)
Connection Diagram (48-54” widths)
Two WM2L Dual Blowers (1200 CFM) (Top View)
(Wall Side)
Centerline
of Hood
Motor
Cooling
Vent (4)
8" [20.3 cm]
Round
5-1/2"
[14 cm]
1-3/4"
[4.4 cm]
5-1/4"
[13.3 cm]
11"
[29.9 cm]
11"
[29.9 cm]
8" [20.3 cm]
Round
INSTALLATION
(CONT.)
©2020 Hestan Commercial Corporation
13