ILVE 60cm Natural Gas Cooktop ILBV604

User Manual - Page 8

For ILBV604.

PDF File Manual, 12 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Installation
This appliance is not provided with a combustion
product discharge. It is recommended that it be installed
insufficiently aerated places, in terms of the laws in force.
The quantity of air which is necessary for combustion
must not be below 2.0 m
3
/h for each kW of installed
power. See table of burner power.
Positioning (Fig. 4)
The appliance can be fitted into a working area
as illustrated on the corresponding figure. Before
positioning the hob, fit the seal around the entire
periphery of the hole cut in the worktop.
Instructions for the installer
This appliance shall be installed only by authorised
persons and in accordance with the manufacturer's
installation instructions, local gas fitting regulations,
municipal building codes, electrical wiring regulations,
AS/NZS 5601 - Gas Installations and any other
statutory regulations.
Gas connection (Fig. 5)
Connect the appliance to the gas cylinder or to the installation according to the prescribed
standards in force, and ensure beforehand, that the appliance matches the type of gas
available. Other wise, see ”Adaptation to various types of gas”. Further more, check that the
feed pressure fall swithin the values described on the table: ”User chacteristics”.
Fig. 5
There are two ways to carry out the connection to the main gas line:
A. The hotplate can be connected with rigid pipe as specified in AS/NZS5601.
B. The hotplate can be connected with a Flexible Hose, which complies with
AS/NZS 1869 (Australian Certified), 10mm ID, class B or D, no more than 1.2m long and
in accordance with AS/NZS 5601. Ensure that the Hose does not contact the hot surfaces
of the hotplate, oven, dishwasher or other appliance that may be installed underneath or
next to the hotplate. WARNING: Ensure that the hose assembly is restrained from accidental
contact with the flue or flue outlet of an underbench oven. The hose should not be subjected
to abrasion, kinking or permanent deformation and should be able to be inspected along its
entire length. Unions compatible with the hose fittings must be used and connections tested
for gas leaks. The supply connection point shall be accessible with the appliance installed.
The hose assembly shall be suitable for connection to a fixed consumer piping outlet
located at a point 800mm to 850mm above the floor and in a region outside the width
of the appliance to a distance of 250mm.
Data Label
The Data Label is located on the base of the
appliance. A duplicate Data Label is supplied
to adhere in an accessible area next to the
appliance. This appliance is suitable for
Natural Gas and ULPG; ensure that the
available gas supply matches the Data Label.
Loading ...
Loading ...
Loading ...