USER CHARACTERISTICS
GAS BURNERS
Before Leaving
Check all connections for gas leaks with soap and water. DO NOT use a naked ame for detecting leaks. Ignite all burners
both individually and concurrently to ensure correct operation of gas valves, burners and ignition. Turn gas taps to low
ame position and observe stability of the ame for each burner individually and concurrently. When satised with the
hotplate, please instruct the user on the correct method of operation. In case the appliance fails to operate correctly after all
checks have been carried out, refer to the authorised service provider in your area.
TYPE PRESSURE mbar
NORM.
BURNER
Ø INJECTORS
1/100
NOMINAL GAS CONSUMPTION
Natural gas 1.00 kPa
fast 155 11.7
semifast 117 6.9
auxiliary 92 4.1
Wok (single control) 180 14.4
Wok Dual
130 (outer)
17.5 (outer & inner)
80 (inner)
Universal
LPG
2.75 kPa
fast 94 11.9
semifast 70 6.5
auxiliary 56 4.1
Wok (single control) 108 14.4
Wok Dual
70 (outer)
48 (inner)
MJ/h
3.2 (inner)
16.0 (outer & inner)
2.9 (inner)